Original source · versioned page text
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions
Including amendments to 3 July 2017
Flooding and drainage51
The Noosa Plan
O7 Buildings and other works are designed and S7.1 For new buildings or structures or
sited to— additions of more than 50m2 gross floor area
a) provide flood free access to premises and to an existing building or structure, floor
flood free habitable areas; levels for habitable rooms are—
b) allow only minor, short term and infrequent a) for areas where minimum floor levels
flooding of non-habitable areas; are available—not less than the
c) ensure carparking areas can be adequately specified level;
drained; b) for areas where flood modelling is
d) ensure drainage does not adversely impact available—a minimum of 300mm
upon other premises; and above the modelled flood level; and
e) ensure filling or excavation does not c) for areas where flood modelling is not
adversely impact upon other premises by— available, a minimum of 300mm
i. causing ponding on the site or nearby above the highest known flood level;
land; AND
ii. increasing flooding, which adversely S7.2 Dwelling houses are raised above
affects the safety or use of any land ground with a suspended floor, rather than
upstream and downstream; and utilising "slab on ground" construction;
iii. adversely affecting the flow of water in AND
any overland flow path. S7.3 Development minimises the impact of
earthworks associated with its building,
access and service provision;
AND
S7.4 Drainage works are designed to
disperse stormwater runoff, rather than
concentrating it.
AND
S7.5 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by gravity
means, without the need for mechanical
pumping; or
S7.6 Basements for residential uses have
flood immunity above the 1%AEP define
flood event where alternative means to
mechanical pumping are used to achieve
such immunity; or
S7.7 Basements for non-residential uses
have flood immunity above the 1%AEP
define flood event that may be achieved by
means of mechanical pumping where the
mechanical feature is installed with
adequate holding tanks and an alternative
back up power source.
Roof form
O8 Rooflines— S8.1 The main roof of the building has a
a) contribute positively to the local skyline; roof pitch no less than 5 degrees and has
b) complement the beachside and riverside minimum 600mm eaves to at least 75% of
character of the locality; the perimeter of the building.
c) avoid low pitched (eg. less than 5 degrees) or
box roof profiles/parapets; and
d) do not create opportunities for residents to
overlook the private open space areas of
neighbouring properties.
51
Information on minimum floor levels and flood levels for some parts of the Shire is available from Council. These
provisions are not limited to areas shown as Flood Hazard Areas on overlay maps OM1.3-9.3.