2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions
g) Precinct E5- 0.6, except for Industrial business
uses;
Including amendments to 3 July 2017
The Noosa Plan
h) Precinct E6- 0.6;
i) Precinct E7- 0.6;
j) Precinct RES- 0.6; and
k) Precinct REC/MU- 0.1.
Flooding and drainage73
O17 Buildings and other works are designed and S17.1 For new buildings or structures or
sited to— additions of more than 50m2 gross floor area
a) provide flood free access to premises and to an existing building or structure, floor
flood free habitable areas; levels for habitable rooms are not less than
b) allow only minor, short term and infrequent the specified minimum floor levels;
flooding of non-habitable areas; AND
c) ensure carparking areas can be adequately S17.2 Where Council infrastructure is
drained; available—
d) ensure drainage does not adversely impact a) any drainage (including buildings and
upon other premises; and yards) flows to that infrastructure; and
e) ensure filling or excavation does not b) the infrastructure has the capacity to
adversely impact upon other premises by— accept any additional loading;
i. causing ponding on the site or nearby AND
land; S17.3 For Residential Uses—
ii. increasing flooding, which adversely a) where slab on ground construction is
affects the safety or use of any land used, filling does not extend more than
upstream and downstream; and 1m beyond the building footprint and
iii. adversely affecting the flow of water in access to car parking areas, measured
any overland flow path. from the outer walls of the building ; or
b) the design consists of a suspended floor
construction;
AND
S17.4 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by gravity
means, without the need for mechanical
pumping;
AND
S17.5 Basements for residential uses have
flood immunity above the 1%AEP defined
flood event where alternative means to
mechanical pumping are used to achieve
such immunity; or
S17.6 Basements for non-residential uses
have flood immunity above the 1%AEP
defined flood event that may be achieved by
means of mechanical pumping where the
mechanical feature is installed with
adequate holding tanks and an alternative
back up power source.
73
Council has mapping of minimum floor levels and flood levels for some parts of the Shire. Contact the Land Development
Section of Council, Tewantin Office.