2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Including amendments to 3 July 2017
Specific Outcomes Probable solutions
The Noosa Plan
in persons multiplied by 40m 2.
O10 For the Neighbourhood Centre Zone and the
Business Centre Zone the maximum plot ratio does
not exceed—
a) 0.8:1 for the first 2,000m 2 of site areas; plus
b) 0.3:1 for the balance of the site areas in excess
of 2,000m2.
Flooding and drainage74
O11 Buildings and other works are designed and S11.1 For new buildings or structures or
sited to— additions of more than 50m2 gross floor area
a) provide flood free access to premises and to an existing building or structure, floor
flood free habitable areas; levels for habitable rooms are—
b) allow only minor, short term and infrequent a) for areas where minimum floor levels
flooding of non-habitable areas; are available—not less than the
c) ensure carparking areas can be adequately specified level;
drained; b) for areas where flood modelling is
d) ensure drainage does not adversely impact available—a minimum of 300mm
upon other premises; and above the modelled flood level; and
e) ensure filling or excavation does not c) for areas where flood modelling is not
adversely impact upon other premises by— available, a minimum of 300mm
i. causing ponding of water on the site or above the highest known flood level;
nearby land; AND
ii. increasing flooding, which adversely S11.2 Where Council infrastructure is
affects the safety or use of any land available—
upstream and downstream; and a) any drainage (from buildings and
iii. adversely affecting the flow of water in land) flows to that infrastructure; and
any overland flow path. b) the infrastructure has the capacity to
accept any additional loading;
AND
S11.3 For Residential Uses—
a) where slab on ground construction is
used, filling does not extend more than
1m beyond the building footprint and
access to car parking areas, measured
from outer walls of the building; or
b) the design consists of a suspended floor
construction;
AND
S11.4 Car parking and maneuvering areas
are constructed at a level that permits the
parking area to drain from the site by gravity
means, without the need for mechanical
pumping; or
S11.5 Basements for residential uses have
flood immunity above the 1%AEP defined
flood event where alternative means to
mechanical pumping are used to achieve
such immunity; or
S11.6 Basements for non-residential uses
have flood immunity above the 1%AEP
defined flood event that may be achieved by
means of mechanical pumping where the
mechanical feature is installed with
74
Information on minimum floor levels and flood levels for some parts of the Shire is available from Council. These
provisions are not limited to areas shown as Flood Hazard Areas on overlay maps OM1.3-9.3.