Skip to the record
Accept no substitutions.

Original source · versioned page text

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections

of 862

Page text shows just the words. Original shows the document exactly as it was published.

                    column 1                                         column 2




                                                                                                              Including amendments to 3 July 2017
                Specific Outcomes                                Probable solutions




                                                                                                  The Noosa Plan
Setbacks
O5 Buildings and other structures are                 S5.1 Buildings and structures comply with
appropriately designed and sited to—                  the setbacks specified in Schedule 1 -
a)     provide amenity for users of the premises as Minimum Boundary Setbacks.
       well as preserve the visual and acoustic
       privacy of adjoining and nearby land uses;
b)     preserve any existing vegetation that will
       buffer the proposed building from adjoining
       uses;
c)     allow for landscaping to be provided between
       buildings; and
d)     maintain the visual continuity and pattern of
       buildings and landscape elements within the
       street; and
e)     help protect the natural character and visual
       amenity of the Noosa River system and other
       watercourses and lakes.
Site cover, gross floor area and plot ratio
O6 The site cover, gross floor area and plot ratio    No solution provided
of buildings and other roofed structures—
a)     results in a building scale that is compatible
       with surrounding development;
b)     does not present an appearance of bulk to
       adjacent properties, roads or other areas in
       the vicinity of the site;
c)     maximises the retention of existing vegetation
       and allows for soft landscaping between
       buildings;
d)     allows for adequate area at ground level for
       outdoor recreation, entertainment, clothes
       drying and other site facilities; and
e)     facilitates onsite stormwater management and
       vehicular access.

O7 Site cover—
a) for a class 1 or class 10a building within a
   Detached Housing Zone, does not exceed—
     i     for a single storey building - 50%; or
     ii    for a building of 2 or more storeys - 50%
           on the ground floor and 30% for the
           upper storey(s), or 40% for all storeys
           for a building of 2 or more storeys;
b) for other classes within a Detached Housing
   Zone does not exceed—40%;
c) for the Semi-Attached Housing Zone does not
   exceed 40%; or
d) for the Attached Housing Zone does not
   exceed 40%.

O8 For Multiple Housing Type 2 development
has a maximum plot ratio of 0.45:1.

O9 For Multiple housing Types 3 or 4, Visitor
accommodation Type 4 or the accommodation
unit component of an Entertainment and dining
business Type 3— the maximum gross floor area
is equivalent to the maximum allowable population



                                               12-43
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)