Original source · versioned page text
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
Table 13.8 Landslide hazard areas
Including amendments to 3 July 2017
column 1 column 2
The Noosa Plan
Specific outcomes Acceptable solutions (if accepted
development )
Probable solutions (if code assessment)
13.32 Effects of use
General
O1 Development is located to ensure it does not S1.1 The proposed development is not
compromise the safety of people, property or located in a landslide hazard area as
hazardous materials manufactured or stored in bulk indicated on Overlay Maps OM1.3-OM9.335;
by increasing risk of landslide; OR
S1.2 The development site is not subject to
AND landslide, either internally or from sloping
land above the site eg. slopes are less than
1 in 10 (10%)
AND
S1.3 Development, including necessary
earthworks within Precinct F of the Noosa
Springs site, improves the stability of any
non-natural landform so it is not at risk from
landslide either on the site or from sloping
land above the site.
O2 Development, including access ways is S2.1 No solution provided
designed and constructed to—
a) minimise impacts on the natural landform;
b) minimise risk to people and property from
landslide;
c) avoid any potential instability and associated
problems, including long term stability of the site
and long term stability of the development.
Protection of Infrastructure and Community
Uses S3.1 Community Uses and Infrastructure
O3 Community Uses and Infrastructure Uses, Uses are not located in a landslide hazard
including that identified below, are able to function area as indicated on Overlay Maps OM1.3-
effectively during and immediately after landslide OM9.3;
events— OR
a) Emergency service facilities; S3.2 The community infrastructure
b) Hospitals; development—
c) Education Type 4 uses, including stores for
a) does not result in any new building
valuable records or items of historic or cultural
work other than an addition to an
significance; and
existing building;
d) Service and utility uses, including electricity
substations, major electrical depots and water b) does not involve vegetation clearing;
treatment plants. and
c) does not alter ground levels or
stormwater conditions;
OR
S3.3 The development includes measures
that ensure—
a) the long term stability of the site;
b) access to the site will not be impeded
by a landslide event; and
35
If Acceptable Solution 1.1 is complied with no further action is required. PSP1 details information Council may request to
determine whether or not the site is at risk from landslide.
13-40
Natural Hazards and Natural Resources Overlays
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file