Original source · versioned page text
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Specific Outcomes Probable solutions
Including amendments to 3 July 2017
13.36 Vehicle access and fire trails
The Noosa Plan
Firebreaks and fire access tracks
O9 Firebreaks or fire access tracks provide— S9.1 Firebreaks are provided by—
a) adequate access for fire fighting and a) a cleared road reserve not less than 20m
other emergency vehicles; and wide located around the perimeter of the
b) adequate width to minimise the risk of development;
fire crossover. OR
b) fire access tracks between the
development and surrounding vegetated
lands that—
i. are a minimum cleared width of 6m;
ii. have a maximum grade of 1 in 8
(12.5%) ;
iii. have a formed pavement;
iv. have access at each end and in other
locations where necessary;
v. have passing areas and turning areas;
vi. have clearly identified access points for
emergency vehicles; and
vii. are located on public land or within
access easements that are granted in
favour of the Noosa Council and the
Queensland Fire and Rescue Service.41
13.37 Reconfiguring a Lot
General
O10 The safety of people and property are S10.1 The proposed lots are not located on land
maintained by that is subject to Bushfire Hazard42;
a) Locating house site areas and other OR
sensitive uses on that part of the land S10.2 The proposed lots are sited on land
least affected by the bushfire hazard; determined as low bushfire risk by a site specific
and bushfire hazard assessment.43
b) fire mitigation methods are used that are AND
adequate for the Potential Bushfire S10.3 Additional lots are not created where their
Hazard rating of the individual site, only vehicular access route is through a Bushfire
having regard to – Hazard area .
i. vegetation type;
ii. slope;
iii. aspect;
iv. on-site and off-site fire hazard
implications of the development;
v. bushfire history;
vi. conservation values of the site; and
vii. ongoing maintenance.
41
Where Council has not previously approved a Bushfire Management Plan for premises, Council may request the
proponent to prepare a plan, as per PSP1 Information Council May Request. Appendix 9 of the SPP Guideline: Mitigating
the Adverse Impacts of Flood, Bushfire and Landslide provides more information on Bushfire Management Plans.
42
PSP1 details information Council may request to determine whether or not the land is in a Bushfire Hazard Area.
43
A site specific bushfire hazard assessment is necessary to demonstrate that although the site is identified within a
Bushfire Hazard Area, the bushfire risk is low as per PSP1 detailing the site specific assessment of bushfire risk prepared
in accordance with Appendix 3 of the SPP Guidelines: Mitigating the Adverse Impacts of Flood, Bushfire and Landslide.