2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections

of 862

Page text shows just the words. Original shows the document exactly as it was published.

                                                                     column 1                                             column 2
                                                                Specific Outcomes                                     Probable solutions
            Including amendments to 3 July 2017
The Noosa Plan



                                                  Hazardous materials
                                                  O6 Public safety and the environment are not        S6.1 Hazardous materials are not manufactured
                                                  adversely affected by the detrimental impacts       and stored in a Bushfire Hazard Area.
                                                  of bushfire on hazardous materials
                                                  manufactured or stored in bulk.
                                                  13.34    Siting, design and construction
                                                  O7 Uses and works including building works          S7.1 Uses and works including building works
                                                  13.34.1
                                                  are sited, designed and constructed to—             are sited—
                                                  a)     minimise the number of people and            a)     on lots greater than 2500m2;
                                                         property subject to bushfire risk; and              i)     in locations of lowest hazard within
                                                  b)     maximise the protection of people and                       the lot (Figure 13.5 provides
                                                         property during the passage of a fire                       guidance); and
                                                         front.                                              ii)    to achieve setbacks from hazardous
                                                                                                                     vegetation of 1.5 times the
                                                                                                                     predominant mature canopy tree
                                                                                                                     height or 10m whichever is the
                                                                                                                     greater; and
                                                                                                             iii)   10m from any retained vegetation
                                                                                                                     strips or small areas of vegetation;
                                                                                                                     and
                                                                                                             iv)    so that the elements of the
                                                                                                                     development least susceptible to fire
                                                                                                                     are sited closest to the bushfire
                                                                                                                     hazard;
                                                                                                      b)      on lots 2500m2 or less - to maximise
                                                                                                           setbacks from hazardous vegetation37

                                                  13.35    Water supply for fire fighting
                                                  O8 An adequate and accessible water supply          S8.1 For premises not in a water service area—
                                                  is provided for fire fighting purposes can be       each lot has an accessible dam, swimming pool
                                                  accessed by fire fighting appliances.               or water tank accessible by the fire brigade that
                                                                                                      contains at least 5000 litres of water.




                                                                                                   13-42
                                                                               Natural Hazards and Natural Resources Overlays
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.