                                                                                       Division 16—Existing Services Code
The Noosa Plan




                                                  14.125 Existing Services Code
                                                           The provisions in this division comprise the Existing Services Code. They are—
                                                              compliance with the Existing Services Code (section 14.127);

                                                              overall outcomes for the Existing Services Code (section 14.128); and

                                                              specific outcomes and probable solution for the Existing Services Code (section
                                                               14.129).

                                                  14.126 Compliance with the Existing Services Code
                                                           Development that is consistent with the specific outcomes in section 14.129 complies
                                                           with the Existing Services Code.

                                                  14.127 Overall outcomes for the Existing Services Code
                                                  14.127.1 The overall outcomes are the purpose of the Existing Services Code.

                                                  14.127.2 The overall outcomes sought for the Existing Services Code are the following—
                                                  a)   Existing Council owned underground infrastructure is protected from potential or actual
                                                       damage caused by development;
                                                  b)   Underground infrastructure is accessible for maintenance purposes; and
                                                  c)   Existing services are identified and methods of protection and access are implemented in the
                                                       design of the development.

                                                  14.128 Specific outcomes and probable solutions for the Existing Services
                                                         Code
                                                           The specific outcomes sought for the Existing Services Code are included in column 1 of
                                                           Table 14-54. Probable solutions for code assessment development are included in
                                                           column 2 of Table 14-54.
                                                  Table 14-54 Existing Services
                                                                     column 1                                           column 2
                                                                Specific Outcomes                        Probable solutions (if code assessment)
                                                  Setbacks and easements
                                                  O1 Development near a sewer, water main,            S1.1 The footing of any structure or building is
                                                  stormwater drain, overland flow path or             located clear of the zone of influence but no
                                                  associated structure does not—                      closer than 1.5m (measured horizontally) from
                                                  a)   adversely affect the function of the           infrastructure including sewers, water mains and
                                                       service;                                       stormwater structures;
                                                  b)   place an additional load on the service;       AND
                                                       and                                            S1.2 No building or structure overhangs the
                                                  c)   unduly increase future maintenance costs.      zone of influence;
                                                                                                      AND
                                                                                                      S1.3 Finished surface levels maintain a
                                                                                                      minimum of 600mm of cover, but no greater
                                                                                                      than 3m of cover to the underground
                                                                                                      infrastructure;
                                                                                                      AND
                                                                                                      S1.4 If the existing surface level is altered,
                                                                                                      surface level services including manholes and
                                                                                                      inspection points are altered to match the new

                                                                                                  14-132
                                                                                          Existing Services Code

Used in these records

About this file

File size
9.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.