Council archive · source document
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections
column 1 column 2
Including amendments to 3 July 2017
The Noosa Plan
Specific Outcomes Probable solutions (if code assessment)
b) have navigational signs generally in
accordance with the Manual for Uniform
Traffic Control Devices Bicycle Directional
Signage Guidelines, and Australian
Standard 1742.9: 2000 Manual of Uniform
Traffic Control Devices Bicycle Facilities;
c) be clearly delineated by pavement
markings and warning signs when an on-
road bicycle lane;
d) incorporate kerb ramps at all intersections
and designated crossings;
e) have refuge islands on all roads with
median strips;
f) have holding rails for cyclists at the
intersection of district collector, sub-
arterial and arterial roads that are
positioned in accordance with Australian
Standard 1742.9:2000 – Manual of
Uniform Traffic Control Devices Bicycle
Facilities, and AUSTROADS Part 14
Bicycles Section 9;
g) have marked bicycle lanes, bicycle; AND
awareness zones or storage boxes; and
h) Include lighting to pedestrian and cycle
pathways to local government
requirements and in accordance with
Australian Standard 1583.1 Road Lighting
– Pedestrian area (Category P) lighting.
O9 The subdivision layout is designed to S9.1 Where there is no relevant approved
facilitate linkages with adjoining sites in the master plan, concept plan, or site analysis plan,
immediate area. subdivision design incorporates future road,
street, cycleway and pedestrian path and open
space connections to adjoining sites.
O10 Where the lots are to be used for No solution provided.
Industrial business or Commercial business
uses, the layout provides for appropriate buffer
areas, to mitigate possible impacts on nearby
residences or other noise sensitive uses.
O11 For lots in the Rural Settlement Zone—a No prescribed solution.
sealed access to the nearest urban settlement
is available.
14.187 Water supply for fire fighting
O12 An adequate and accessible water supply S12.1 For development in a water service area,
is provided for fire fighting purposes. water mains within the development shall
comply with the:
a) Queensland Water Resource Commission -
Guidelines for Planning and Design of
Urban Water Supply Schemes; and
b) Australian Standard 2419 and the Water
Providers Network Model Criteria;
14-180
Reconfiguring a Lot Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections.pdfRelated documentPublic source context ↗