Council archive · source document
IDAS Code responses · OPW15/0240
Attached to the e-mail OPW15/0240 - Operational Works Application.
_____________________________________________________________________________________________________________Callaghan and Toth Pty Ltd
least 3m inside of the side boundary or extended side boundary of
the lot connected to the boardwalk or deck;
(c) if a relevant planning scheme standard is more stringent than the
standard mentioned in paragraph (a) or (b)—the relevant planning
scheme standard, to the extent it is more stringent than the standard
mentioned in paragraph (a) or (b).
Design, construction and safety—boat ramps and slip ways for private purpose
13.1 Prescribed tidal work that is a private boat ramp or (s 6(2) solution) N/A
private slip way is designed and constructed in a way to The design and construction of the boat ramp or slip way is consistent
ensure it is structurally sound while also ensuring the top with the following standards—
of each wall at the edge of the boat ramp or slip (a) subject to paragraph (c), the walls at the edge of a boat
way is level with the surface of the land on which the ramp or slip way penetrate into the earth at least 600mm below the
boat ramp or slip way is located. surface of the land on which the boat ramp or slip way is located;
(b) subject to paragraph (c), the surface of a boat ramp or slip way is
no more than 200mm above the surface of the land on which it is
located;
(c) if a relevant planning scheme standard is more stringent than the
standard mentioned in paragraph (a) or (b)—the relevant planning
scheme standard, to the extent it is more stringent than the standard
mentioned in paragraph (a) or (b).
13.2 Prescribed tidal work that is a private boat ramp or (s 6(2) solution) N/A
private slip way is designed and constructed in a way to The design and construction of the boat ramp or slip way is consistent
ensure the safe movement of vehicles or persons over with the following standards—
the boat ramp or slip way. (a) subject to paragraph (d), the upper surface of a boat ramp
or slip way has a width of no less than 3.6m;
(b) subject to paragraph (d), the whole upper surface of a boat ramp or
slip way is treated to prevent it from becoming slippery by using
any of the following methods—
(i) forming grooves over the surface, as close as possible to 40mm
wide, 20mm deep and 150mm apart, and at an angle as close as
possible to 70° to the centre-line of the boat ramp or slip way;
(ii) covering the surface with a substance ordinarily used on
slippery surfaces to prevent skidding;
(iii) making, through a physical act, the surface coarse before it sets,
including, for example,by raking the surface; (c) subject to paragraph
(d), the upper surface of a boat ramp or slip way for which a
winch is not used to hoist or haul vessels onto the boat ramp or slip
way is at a gradient of not steeper than—
IDAS Code Responses_Rising Main Works_MossmanCourttoSerenityClose pg. 9