6. Appendix C - Noosa Assessment Benchmark Assessment
Division 13 – Driveways and Carparking Code
Table 14.49 – Driveways
Specific Outcomes Probable Solutions Response
14.112 General
O1 S1.1 The proposal complies with the
probable solutions as the access
Vehicular access does not Vehicular access is located and
allows for the minimum widths and
adversely impact on safety, designed in accordance with
maximum allowable grades and
capacity and operations of the AS/NZS2890.1:2004; AND
transitions in accordance with the
existing or planned road network,
the proposed driveway, cycleways standard.
or pedestrian pathway systems S1.2 Only one footpath crossing is
provided at the Hofmann Drive
Only one footpath crossing is
main entrance.
provided26; AND
S1.3 No Applicable Council Standard.
Driveways, have a maximum Driveways have been designed
grade in accordance with with a maximum fall of less than
1:20 which exceeds the standard
Council’s standard requirements.
requirements.
O2 S2.1 The pertaining Council standard
Driveways and crossovers— Design of the driveway across the drawings is RS-049 for Driveway
Prohibited Locations. The
footpath is in accordance with
a) are suitable and safe for their proposed crossover is in the same
Council’s Standard Drawing
intended use; and location as the existing crossover.
requirements as appropriate for
b) match Council infrastructure. the particular type of development
as annotated on the drawings;
AND
S2.2 As above. To be documented in
Driveways are designed and the detailed design phase.
constructed in accordance with
Council Standard Drawing
requirements , as appropriate for
the particular type of development
as annotated on the drawings;
AND
S2.3 No Applicable Council Standard.
Driveways have been designed
The change in grades in the
with changes in grade in
driveways and ramps is in
accordance with Australian
accordance with Council’s
Standard requirements.
Standard Drawing requirements
O3 S3.1 As per the proposal.
In commercial zoned areas, the Design of multi-tenanted
number of driveways across developments in commercial
pedestrian footpaths is minimised. zoned areas include shared
driveways and parking areas; AND
S3.2 As per the proposal.
Driveways are located so they
abut existing driveways of