23110 Op Works Issue 20-12-2023

of 13

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                                                                                                                                                                                                            50 - 150


NOTES:                                                                          NOTES                                                                                                              GROUNDCOVER PLANTING
                                                                                                                                                                                                   STONE STEPPER 40mm THICK
-REFER MATERIALS & FINISHES SCHEDULE FOR                                        - FALL ALL PIPES TO EVENLY TO STORM WATER SYSTEM.
FERTILISER APPLICATION REQUIREMENTS                                                                                                                                                                COMPACTED ROAD BASE 150mm DEPTH
                                                                                - JOIN DRAINS TO UPVC CONDUITS OF SAME DIAMETER WHEN
                                                                                PLACING UNDER PAVED AREAS OR ANY OTHER AREAS WHICH
TURF                                                                            REQUIRE A COMPACTED SUB-BASE.                                                                                      IMPORTED SOIL BLEND 150mm DEEP
                                                                                                                                                                                                   COMPACTED SUB GRADE
                                                                                - SUB-SOIL PIPE TO BE 90MM DIAMETER WITH FILTER SOCK.
                                      FSL

IMPORTED SOIL BLEND MIN 100mm DEEP




                                                                                                                                                        VARIES
CULTIVATED SUBGRADE -150mm                                                                                                                                                                                 STONE STEPPERS - PA1 & PA2
                                                                                                                                                                                                    6       1 : 20
         TURF AREA - TU1                                                        BIDIM A12 GEOTEXTILE FABRIC OR

  1                                                                             APPROVED EQUIVALENT




                                                                                                                                                        300
           1 : 20                                                               SUB-SOIL PIPE

                                                                                10-20mm DRAINAGE GRAVEL
                                                                                                                                                                                                   NOTES:
                                                                                                                                                                                                   - MOUND IMPORTED SOIL BLEND
                                                                                                                                      300
                                                                                                                                                                                                   300MM TO CENTRE OF PLANTER                                                       WIDTH VARIES
NOTES:
                                                                                          SUBSOIL DRAIN - SSD                                                                                      SCREW CAP TO CLEAN-OUT RISER
-REFER MATERIALS & FINISHES SCHEDULE FOR
FERTILISER APPLICATION REQUIREMENTS
                                                                                 4            1 : 20
                                     FSL
                                                                                                                                                                                                   MULCH - TO FINISH LEVEL WITH TOP OF
MULCH                                                                                                                                                                                              PLANTER WALL

IMPORTED SOIL BLEND MIN 300 DEEP                                                NOTES:

                                                                                - PLACE THE ROOTBALL ON A FIRMED BASE TO ACHIEVE REQUIRED FSL.
                                                                                - THOROUGHLY WATER THE ROOT BALL IMMEDIATELY AFTER PLANTING.
                                                                                                                                                                                                   PLANTER WALL
                                                                                - NUMBER OF STAKES WILL VARY WITH POT SIZE. REFER PLANT
                                                                                SCHEDULE.




                                                                                                                                                                                                                                                                                                                                  300
CULTIVATED SUBGRADE -150mm                                                                                                                                                                         IMPORTED SOIL BLEND - HORIZON A
                                                                                - CULTIVATE SIDES OF EXCAVATED HOLE 50MM.
                                                                                                                                                                                                   WATERPROOFING AND PROTECTION BOARD
                                                                                PLANT STOCK
         PLANTING AREA - PL1
  2        1 : 20                                                               HARDWOOD STAKE- 38 X 38                                                                                            IMPORTED SOIL BLEND - HORIZON B




                                                                                                                                                                                                                                                                                                                                        HEIGHT VARIES
                                                                                X1800MM. PLACE 600MM OF INTO
                                                                                THE GROUND. DO NOT PLACE                                                                                           DRAINAGE CELL AND FILTER FABRIC
                                                                                THROUGH ROOTBALL. SECURE
                                                                                WITH TIES BY LOOPING IN A
NOTES:                                                                          FIGURE EIGHT PATTERN.
                                                                                                                                                                                                   CLEAN-OUT RISER (WHERE REQUIRED) -
- PLACE THE ROOTBALL ON A FIRMED BASE TO                                                                                                                                                           RIGID SLOTTED PVC PIPE SOCKED IN GEO-
ACHIEVE REQUIRED FSL.                                                           TOP OF ROOTBALL TO FINISH 20mm                                                                                     TEXTILE FILTER FABRIC
- THOROUGHLY WATER THE ROOT BALL                                                BELOW FINISHED SOIL LEVEL.
IMMEDIATELY AFTER PLANTING.                                                     FORM SHALLOW DEPRESSION IN
- CULTIVATE SIDES OF EXCAVATED HOLE 50MM.                                       SOIL AROUND ROOTBALL FOR
                                                                                WATER RETENTION. SEPARATE
PLANT STOCK -RAISE PLANT 25MM
                                                                                MULCH 100mm FROM TREE TRUNK.
ABOVE SOIL SURFACE LEVEL.
                                                                                                                                                                                                   GEO-TEXTILE FILTER FABRIC
MULCH - PULL AWAY FROM BASE OF                                                  FORM EARTHEN BASIN                                                                                                 COARSE WASHED SAND
PLANT                                                                           AROUND BASE OF PLANT.

FORM EARTHEN BASIN AROUND BASE
OF PLANT.                                                                               FSL
                       FSL                                                                                                                                                                         DRAINAGE CELL AND FILTER FABRIC



                                                                  1                                                            ROOTBALL
FERTILISER- DO NOT ALLOW                                                                                                                                                                           PLANTER DRAIN
                                                              1
CONTACT WITH ROOTS.
                                                                                                                                                                 1                                 STRUCTURAL SLAB
ROOTBALL
                                             w                                                                                                           1
                                                                                IMPORTED SOIL BLEND
                                            2xw
                                                                                                                                                                                                           PLANTING AREA - PL2
                                                                                FERTILISER- DO NOT
                                                                                ALLOW FERTILISER TO
                                                                                COME IN CONTACT WITH
                                                                                                                                                                                                    7       1 : 20
         GENERAL PLANTING
  3
                                                                                ROOTS.                                         WIDTH (w)
                                                                                                                                 2xw
           1 : 20



                                                                                          ADVANCED PLANTING
                                                                                  5           1 : 20




                                                 [email protected]          David Low Way Duplex                                          LANDSCAPE DETAILS                                                         Project No.     Drawing   Issue   Scale                 NOT FOR CONSTRUCTION
                                                                                                                                                                                                                           23110           LA4-001   C       1 : 20   @A3
                                                 9 Fort Lane
                                                 Milton Qld 4064
                                                                                   206 David Low Way, Peregian Beach                                                                                                                                                               Issue   Date         Purpose          Drawn   Approved
                                                 PO Box 287                                                                                                                                                                                                                        A       11-10-2023   DRAFT ISSUE      GG      AG
                                                 Paddington Qld 4064                                                                                                                                                                                                               B       12-10-2023   OP WORKS ISSUE   GG      AG
                                                                                                                                                 ©2022 Wild Studio Australia Pty Ltd. These                                                                                        C       13-12-2023   OP WORKS ISSUE   GG      AG
                                                 urban landscape architecture                                                                    drawings are protected by copyright and may not
                                                 wildstudio.com.au                 Client: Adam Offermann and Madeleine Swete Kelly              be amended or reproduced without authorisation.
Log in to download the original file

23110 OP WORKS ISSUE 20-12-2023.pdf · 1.6 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.