Original source · versioned page text
Effluent Disposal Approval northern unit
1 Background
Taylor Environmental (Australia) Pty Ltd was engaged to design an on-site wastewater
treatment and effluent disposal system at 53 Martins Road, Cooroy QLD 4563. This property
is not serviced by a municipal sewer network and requires a wastewater treatment and effluent
disposal system.
The site location is displayed in Figure 1, below.
Figure 1: Site Location
The design was completed by Chris Taylor (Director, Taylor Environmental (Australia) Pty Ltd,
QBCC Licence Number 150 556 72).
2 Legislation and Standards
This report has been completed in accordance with the relevant legislative requirements:
● Plumbing and Drainage Act
● Plumbing and Drainage Regulation
● Queensland Plumbing and Wastewater Code
● AS/NZS 1547:2012 On-site Domestic Wastewater Management
● Plumbing Code of Australia (PCA)
3 Effluent Standards
Table 1 below presents the effluent standards produced by approved wastewater treatment
systems with beds or trenches.
Table 1: Effluent Quality
Parameter Secondary Advanced Secondary
90% < 20 mg/L 90% <10 mg/L
Biochemical Oxygen Demand
100% < 30 mg/L 100% <20 mg/L
90% < 30 mg/L 90% < 10 mg/L
Total Suspended Solids
100% < 45 mg/L 100% < 20 mg/L
Site and Soil Evaluation 53 Martins Road, Cooroy QLD 4563
Taylor Environmental (Australia) Pty Ltd Page 2 of 16
Document Set ID: 21598877
Version: 1, Version Date: 30/08/2021
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.