Geotechnical Report
LINDSAY CONSULTING PTY LTD -
STRUCTURAL AND CIVIL ENGINEERS
ACN 079 744 808 ABN 61 478 386 385 GST REGISTERED
AS TRUSTEE FOR THE LINDSAY FAMILY TRUST
SITE CLASSIFICATION REPORT
JOB NUMBER 231061
CLIENT POOLS BY DESIGN
SITE LOCATION No. 5 SEAMIST COURT, SUNSHINE BEACH
REPORT DATE NOVEMBER 2023
1. INTRODUCTION
The purpose of this report is to classify the subject allotment in accordance with
Australian Standard 2870-2011 'Residential Slabs and Footings. From this classification
a footing system has been recommended for the structure so as to allow adequate
performance of the footings under the soil conditions determined at the site.
This report relates exclusively to the proposed pool at subject allotment, as detailed on
the architectural drawings supplied by the client. This document has been prepared for
the express purpose stated above. This document does not cover any other elements
related to construction on the site.
2. SITE DESCRIPTION
The subject allotment is a residential lot fronting a sealed road, there is an existing
residence at the site and the proposed pool is to be located towards the rear. The
proposed site has average grass cover with dense undergrowth and many shrubs and
small trees present, the site falls towards the rear of the block at an approximate slope
of 15%.
3. SOIL PROFILE
The borelogs carried out at the site, refer attached Site Plan for localities, indicate that
the soil profile consists of clayey sand (high organic content - peat) overlying silty sand.
A WATERTABLE was encountered at the time of testing at a depth of 900mm.
Whilst every effort has been made to ensure that the borelogs carried out at the subject
allotment are indicative of the soil profile over the site any discrepancy between the
profile detailed in the borelogs and that observed during construction shall be referred
to the Consulting engineer for immediate attention.
4. MATERIALS LABORATORY TEST RESULTS
Determination of the classification for the site in this situation is based upon test results
from Dynamic Cone Penetrometer testing performed over the site and shrink/swell test
results.
Off. 2C/82 Parker St, Maroochydore 4558
OFFICE: (07) 54 792 118 MOBILE: 0412 313 645 FAX: (07) 54 510 118
E-MAIL: [email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.