Council archive · source document
Appendix D Code Assessment · MCU16/0099.01
Specific Outcomes Probable solutions (if code assessment) Comments
strips and gross pollutant traps, are used wherever treatment is in accordance Healthy Waterways quality and will therefore not require any natural
possible. Water Sensitive Urban Design Guidelines for treatment strategies.
South East Queensland and the Water by
O8 Development design including density and Design Bio retention Technical Design O8 is not applicable
scale provides adequate footprint to integrate all Guideline. The proposed access and power installation to
elements of stormwater quality and quantity the approved facility will not impact on water
treatment infrastructure including, where relevant, bio S9.1 Landscape and ecological features quality or stormwater quality and will therefore not
retention basin batters and maintenance access, (e.g. plant species and habitat types) used in require a bio retention basin or retaining walls.
without the need for retaining walls. stormwater conveyance channels are
complementary to the local context, including O9 is not applicable
O9 Stormwater conveyance channels use natural natural waterways; The proposed access and power installation to
channel design principles to convey external the approved facility will not impact on water
catchment stormwater through the development site AND quality or stormwater quality and will therefore not
and support landscape, passive recreation and require stormwater conveyance channels.
ecological values. S9.2 Planting densities result in a stable
channel over the long term and minimize
potential for invasive weed growth.
O10 Development design and operation facilitates S10.1 Methods to prevent gross pollutants Complies with O10
nil increase in gross pollutants entering stormwater entering stormwater systems and waterways are The proposed access and power installation to
systems. adopted that— the approved facility will have a nil increase in
are low maintenance; gross pollutants entering stormwater systems. No
prevent nutrient leaching in the event pollutants will be produced as a result of the
scheduled maintenance is delayed; and proposal,
facilitate human behaviour change (e.g.
signage, bins).
Project 226420 File Appendix D – Code Assessment 2019-12-10 Revision 2 Page 88