EGX_PROD_n6829410_191_Hollett_Road,_Noosaville_L53_SP163571
Attached to the e-mail 152006.1999.4 - Affected entity response notice -191 Hollett Road Noosaville.
RESPONSE TO DEVELOPMENT APPLICATION ENERGEX Limited acting as an advice agency under the Integrated Planning Act 1997, response to the proposed development is: This application be refused for the following reasons: or x This application be approved in principle subject to the following conditions: When considering any future works either on ENERGEX easements or in the vicinity of ENERGEX assets, please be aware of the following general conditions: Any further proposal for works or development on the easement including those involving changes in ground level and retaining wall designs around towers and poles must have prior approval from ENERGEX. Please submit the relevant civil design to the Principal Mains Design Engineer for approval. Satisfactory clearance from any proposed structure to the existing (and/or future) electricity wires must be maintained in accordance with the Electrical Safety Regulations 2002. No civil works are to occur within 5 metres of any part of a tower base, pole or stay. Trenches in excess of 5metres in depth must have a minimum horizontal séparation, from the trench to any tower base or pole, at least equal to the trench depth. Natural ground levels on the easement should not be disturbed without ENERGEX approval. ENERGEX trenching requirements for the installation of pipe include full depth shoring of trench sides for 5 metres either side of a structure. The trench is not to be left open overnight and backfill is to be compacted in 150mm layers in the immediate vicinity of the structure. Final ground levels should slope gently to the edge of the easement, surrounding area or kerb such that pooling of water on the easement is avoided and conductor ground clearances are not decreased. 10 metres clear access must be provided around all towers and pole structures. Stockpiling of spoil on the easement is prohibited. Lighting structures are not permitted in the easement without prior written consent of ENERGEX. Underground services should be kept to the outer edge of the easement and any crossing of the easement should be clearly marked. Please submit the relevant design drawings to the Principal Mains Design Engineer for review. The identification, assessment and mitigation of any possible hazards in the service due to electromagnetically induced voltages, is the responsibility of the developer. Any cut in the vicinity of a structure or between a structure and the road kerb will need to be stabilised by a retaining wall. The retaining wall design and location is to be submitted to ENERGEX for approval. Reference: HBD313709 - (710/23/11 P23-02) — L1167
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.