be clearly marked. Please submit the relevant design drawings to the Energex for
review.
The identification, assessment and mitigation of any possible hazards in the service
due to electromagnetically induced voltages, is the responsibility of the Developer.
• Any cut in the vicinity of a structure or between a structure and the road kerb will
need to be stabilised by a retaining wall. The retaining wall design and location is to
be submitted to Energex for approval.
• Any costs incurred by Energex as a result of the works on the easement are to be
met by the property Developer / owner.
• Access to the easement and access along the easement must be available to
Energex personnel and heavy equipment at all times. Energex will require the
Developer / owner to supply and install gates where fencing prohibits access to and
along the easement area. To enable travel along the easement at anytime the gates
must be series locked with an Energex padlock. Both the padlock and a design
drawing of an acceptable gate will be provided by Energex.
• At all times the following clearance must be maintained from the top of any
machinery moving in the vicinity of energised conductors:
• 132kV and 110kV conductors – 4.5m minimum clearance
• 33kV and 11kV conductors – 3m minimum clearance
• Should it be necessary to transport equipment or extend any equipment, such
that these clearances cannot be confidently maintained, you are required to
contact our office to ascertain whether a Safety Officer is required on–site. All
operators of machinery are to be made aware of the presence of high voltage
conductors.
• No planting is permitted in the Easement without prior approval from Energex. If
planting is proposed, the applicant is required to provide a Detailed Landscape
Plan to Energex for approval which:
o Keeps the planting of trees to the outer most edge of the easement and
not directly under any overhead conductors; and
o Plots the location of the overhead conductors (accounting for a cross-arm
if applicable and plotting the powerline on the outmost edge of each side
of the cross-arm); and
o Uses species included on Energex’s Safetrees list
(https://www.energex.com.au/about-us/our-commitment/to-the-
environment/vegetation/safetree-program); and
o Ensures a horizontal clearance is achieved between the tree and the
outer most conductor equal to the mature height of the tree.