GENERAL COMMITTEE MEETING AGENDA                                                 14 JANUARY 2019


RECOMMENDATION
That Council note the report by the Coordinator Planning to the General Committee Meeting dated
14 January 2019 regarding Application No. 132006.268.03 for a Pre-Response Request for a Minor
Change to Conditions of Approval situated at 314 Cooroy Mountain Road, Cooroy Mountain and:
A.   Advise the applicant that Council does not support the proposed change to increase truck
     numbers as:
     1.    The proposed changes do not constitute a minor change under the Planning Act 2016
           as the changes would result in a substantially different development.
     2.    The proposal would have a detrimental impact on Cooroy Mountain Road and the
           residential amenity of properties along the truck route.
     3.    The proposal is not consistent with the Cooroy and Lake Macdonald Locality Code as
           it would have adverse impacts on the amenity enjoyed by users of adjoining and nearby
           properties.
B.   Advise the applicant that Council would support a change to the development approval
     subject to conditions 5A, B1, B2 and B3 being included and condition 5C, 8 and 9 amended
     as follows:
     5B.   Prior to the Council completing the staged upgrade works to Cooroy Mountain Road,
           weekly trucks shall be limited as follows:
           (a)     40 water carrying trucks (namely all semi-trailers, tankers and other trucks
                   carrying water but excluding B-Doubles) per week;
           (b)     20 ancillary trucks (namely non-articulated trucks and non-water carrying trucks).
     5C.   After the Council has completed the staged upgrade works to Cooroy Mountain Road,
           weekly trucks shall be limited as follows:
           (a)     50 water carrying trucks (namely all semi-trailers, tankers and other trucks
                   carrying water but excluding B-Doubles) per week;
           (b)     25 ancillary trucks (namely non-articulated trucks and non-water carrying trucks).
           Note: The road upgrade referred to is the upgrading of the remaining 2.2. kilometres of
           Cooroy Mountain Road to provide two (2) 3.5 metre wide traffic lanes with a 1.0 metre
           wide sealed shoulder to a total formation width of 9.0 metres.
     8.    The applicant must undertake improvement works to the existing site access to Cooroy
           Mountain Road to the reasonable satisfaction of Council. The intersection between
           Cooroy Mountain Road and the site access must be designed and constructed to
           provide safe turning areas for the vehicles likely to use the access and passing
           opportunities for other road users. The works must:
                 a. be generally in accordance with drawing number R01 - Revision C prepared by
                    Barlow Shelley Consulting Engineers dated 20 December 2018,
                 b. be designed and constructed in accordance with the most recent edition of the
                    Department of Main Roads Road Planning and Design Manual and The Noosa
                    Plan Planning Scheme Policy 5 Engineering Design Standards - Roads,
                    Drainage and Earthworks, and
                 c. the internal driveway at the access point must be widened sufficiently to ensure
                    that all vehicles exiting the site and travelling west can remain on the southern
                    side of the centreline of the improved Cooroy Mountain Road.
     9.    The full extent of the driveway from Cooroy Mountain Road to the loading area of the
           facility must be sealed, designed and constructed in accordance with AS/NZS2890.1-
           2004, AS2890.2-2002 and The Noosa Plan Planning Scheme Policy 5 Engineering
           Design Standards - Roads, Drainage and Earthworks. The driveway shall be designed

                                                                                       Page 4 of 40
Log in to download the original file

2019-01-14 General Committee Meeting Agenda(PDF, 2MB).pdf · 2.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.