               1.     PROPOSAL
               The application seeks approval to operate an aquaculture facility within an existing industrial shed
               (being approximately 1,112m2 in area) and two additional structures (equating to approximately
               380m2 located along the western boundary) at 14-16 Action Street, Noosaville. The no changes
               are proposed externally to the existing industrial building, with the two additional structures having
               been places on site between June and November 2022.
               The proposed facility is intended to culture marine and freshwater microalgae species in closed
               system bioreactors and will operate in association with the existing research and technology
               industry. The bioreactors are contained within fully enclosed workrooms on the site. Once fully
               operational, the applicant advises this facility is proposed to be equipped with 45 separate
               bioreactors, capable of containing 180,000 litres. The bioreactors will be housed in a securely
               enclosed building with restricted entry. To minimise water consumption and waste water
               generation, a recirculating system is proposed.
               The applicant’s Environmental Management Plan submitted to the SARA includes a detailed
               description of the proposed operations with the pertinent issues included/summarised below:
               Water Management
               The recirculating production system is designed to ensure the efficient utilisation of water resources
               throughout the entire production process. Water is carefully managed, filtered and recycled within
               the closed system, minimising the need for additional water inputs and reducing overall water
               consumption. Furthermore, the design of cleaning and washdown procedures takes into account
               the objective of minimising water consumption.

               Certain species intended for production grow in saline environments. Salt water utilised in
               production will exclusively originate from operators who possess a valid water collection permit.
               External auditing and certification mitigates the risk of unacceptable ecological impacts. Permit
               currency shall be audited in accordance with the Annual Audit Schedule.

               Wastewater Management
               The recirculated algae system minimises the generation of wastewater. The operation at full
               capacity is anticipated to generate approximately 7,000 L per day of wastewater from operation of
               the bioreactors, processing of algal cell mass and cleaning activities. All water used in the
               production system will undergo ultrafiltration and ultraviolet treatment; wastewater will be
               transferred into a holding tank and undergo dose chlorination prior to discharge to the sewer to
               ensure that no viable organisms are discharged to waste.

               Airborne Emissions
               The cultivation of algae in closed system bioreactors will not generate emissions of dusts, vapours,
               gases or other airborne contaminants. Any airborne emissions within the production facility,
               generated independently of the closed bioreactors, will be filtered through the HVAC system (hepa
               filtered) to remove microbial and particulate matter.

               Solid Waste Management
               Minimal solid waste will be generated through the production process. Media packaging materials
               will be appropriately recycled. In the event of unforeseen circumstances requiring the disposal of
               algae, proper treatment will be conducted prior to discharge to ensure the absence of viable cells.

               Noise Assessment
               The planned procedures will utilise closed system bioreactors that operate exclusively within
               enclosed workrooms located in a fully sealed building. It is expected that the noise levels originating
               from the building will not surpass background noise level, making a Noise Management Plan
               unnecessary at this point. If any alterations are made to the operations, noise levels will be
               monitored accordingly.
               The locality and proposal plan are included below.


                                                                                                         Page 2 of 8

Document Set ID: 22408646
Version: 6, Version Date: 15/09/2023

Used in these records

About this file

File size
1.6 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Delegated Report - Code - Planning MCU23 0038 [As Published].pdf · 1.6 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.