Original source · versioned page text
240808 - Sprout As Consturcted 9 BARTLETT RD NOOSAVILLE INDUSTRIAL WAREHOUSES - REV D (002)
Original PDF page 4, section 1. The text section number identifies this passage in the reader.
ARCHITECTURAL SAFETY IN DESIGN REPORT PROJECT DESCRIPTION NEW WAREHOUSE, INDUSTRIAL DEVELOPMENT PROJECT ADDRESS 9 BARTLETT ROAD, NOOSAVILLE, QUEENSLAND LEGISLATION THE FOLLOWING SAFETY AND DESIGN REPORT HAS BEEN COMPLETED IN ACCORDANCE WITH THE FOLLOWING STATUTORY LAWS & REFERENCE DOCUMENTS: - LEGISLATIVE GUIDE - DESIGNER WRITTEN REPORT FOR A STRUCTURE (LG-DR) (WORKPLACE HEALTH AND SAFETY QLD) - WORKPLACE HEALTH AND SAFETY QLD WEBSITE, DESIGNERS OBLIGATIONS. CLIENT OLD SEA DOG 9 PTY LTD - QUEENSLAND GOVERNMENT'S WORKPLACE HEALTH AND SAFETY ACT 2011, QUEENSLAND GOVERMENT. - SAFE DESIGN OF STRUCTURES - CODE OF PRACTICE, SAFE WORK AUSTRALIA. PROJECT ARCHITECT PAUL BRAITHWAITE EXCLUSIONS THIS REPORT AIMS ONLY TO ADDRESS ITEMS SUCH AS SITE CONDITIONS, CONSTRUCTION METHODS AND DESIGN FEATURES THAT ARE UNIQUE OR SPECIFIC TO THIS PROJECT RISK ASSESSMENT MATRIX The following risk assessment matrix has been used to assess the risks associated with identified hazards; each risk is assessed before any control measures are applied (Raw Risk Level) and then reassessed after the suggested control measures are applied in accordance with the applicable standards (Revised Risk Level): CONSEQUENCE OF INCIDENT OCCURING LIKELIHOOD OF INCIDENET OCCURING SCORE RISK CATEGORY ACTION INSIGNIFICANT MINOR MODERATE MAJOR CATASTROPHIC No injuries First Aid only Medical treatment required Extensive injuries Death CERTAIN 2 3 4 4 4 4 ACUTE Risk requires immediate action and attention to mitigate likelihood of consequence. LIKELY 2 3 3 4 4 3 HIGH High level of management attention is required. POSSIBLE 1 2 3 4 4 2 MODERATE Management required through specific monitoring and response procedures. UNLIKELY 1 1 2 3 4 1 LOW Management required through routine procedures. RARE 1 1 2 3 3 SITE HAZARDS These hazards apply to the demolition of existing structures as well as the construction and maintenance of new construction. HAZARD CATAGORY DETAIL OF HAZARD RAW RISK LEVEL RECOMMENDED AND EXISTING REVISED RISK LEVEL ACTION CONTROL MEASURES S1 Access and Egress Access to the site is from a medium traffic road, potential for Recommend contractor provide a traffic management plan for Principal/Maintenance/Demolition Contractor collision with vehicles. 4 the site. 3 S2 Adjoining Areas The site backs onto other industrial areas, potential for persons using Recommend that works are controlled and maintained within the Principal/Maintenance/Demolition Contractor these areas to be injured. 4 site boundaries. 3 S3 Crane Operation Risk of falling objects striking vehicles, pedestrians and users of Contractor to ensure safe access for pedestrians and vehicles; Consider Principal/Maintenance/Demolition Contractor adjoining areas. 4 crane location in relation to adjoining areas. 3 S4 Electrical Works on or near energised electrical installations are defined as Contractor to put in place a Safe Work Method Statement prior to Principal/Maintenance/Demolition Contractor high risk construction work. 4 commencing works. 3 S5 Electrical Risk of contact with underground power. Confirm locations of any underground power prior to works Principal/Maintenance/Demolition Contractor 4 commencing. 3 S6 Noise Risk of noise affecting persons in adjoining buildings. Follow DA Conditions regarding hours of work. Principal/Maintenance/Demolition Contractor 3 2 S7 Underground Contact with underground services including power, gas, Confirm locations of any underground power prior to works Principal/Maintenance/Demolition Contractor telecommunications, sewer, water and stormwater. 4 commencing. 3 Services S8 Earthworks Potential to disturb acid sulfate soils. Develope an acid sulfate soil management plan, refer to geotechnical Principal/Maintenance/Demolition Contractor 3 report for details. 1 Refer to geotechnical report for advice on ground water control, S9 Climatic Conditions Potential site inundation through flooding. dewatering and drainage. Recommend flooding be included in Principal/Maintenance/Demolition Contractor 4 3 emergency plan. S10 Overhead Services Contact with live electricity cables Confirm locations of any overhead power. Liaise with supply authority for Principal/Maintenance/Demolition Contractor 4 3 sheilding/ proping/ diversion of existing services REV DESCRIPTION DRAWN DATE project drawing A BUILDING APPROVAL AC/NN 03/08/22 B BUILDING APPROVAL AC/NN 12/08/22 Suite 2, Suncoast Resort Business Centre PROPOSED NEW INDUSTRIAL SAFETY IN DESIGN REPORT 1 C D BUILDING APPROVAL B.A - AS BUILTS FOR CERTIFICATION KT/AC NN 13/09/22 08/08/24 Cnr Gardak Street SUNCOAST & Surf Road RESORT BUSINESS CENTRE WAREHOUSES Alexandra SUITE 2 Headland Q 4572 CNR GARDAK ST & SURF RD Copyright of this document remains the exclusive for property of SPROUT ARCHITECTS PTY LTD POALEXANDRA HEADLAND Box 6232, Maroochydore BC Q 4558 Qld 4572 ABN 23 123 917 724. PO BOX 6232 MAROOCHYDORE BC Qld 4558 OLD SEA DOG 9 PTY LTD date 8/08/2024 drawn KT/AC scale AS SHOWN Contractors are to verify all dimensions and levels on P PH 07 :5443 5028 07 5443 F 07 5479 2380 | ABN 5028 FAX:07235479 123 917 2380724 at @ A1 site prior to commencing. Report all discrepancies to [email protected] ABN | sproutarchitects.com.au 23 123 917 724 9 BARTLETT ROAD NOOSAVILLE QLD the Architect. Use figured dimensions in preference to scaled. EMAIL: [email protected] drawing no. 21015 CD10.03 revision D
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.