19 Viewland Drive Final Renovation Plans Stage 16 · OPW19/0180
Attached to the e-mail Operational Works Application OPW19/0180 - DA Form 1 - Supporting information document - Plans - Plans - Arborist Report - at 19 Viewland Drive Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES 19 viewland drive, noosa heads 4567 lot 8 on RP88535 TIMBER FRAMING AND CONSTRUCTION 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH RAINFALL CATCHMENT AREA - 232.75SQM THE AUSTRALIAN DOMESTIC BUILDING CODE. DOWNPIPE TYPE AND GUTTERING TO BE CONFIRMED BY OWNER/BUILDER 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH LOCATION AND REQUIRED DOWNPIPES TO BE CONFIRMED BY BUILDER AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN DP ACCORDANCE WITH AS 1684.2 2010 DP DP 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO 600 600 BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL 600 solar tube MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 8.00° 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER solar tube AS NO RESPONSIBILITY WILL BE TAKEN AFTER 600 8.00° CONSTRUCTION HAS COMMENCED 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS solar tube 3660.1.2000 DOMESTIC SMOKE ALARMS 8.00° 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT REGULATION 2016 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL 600 AND INTERCOM SYSTEMS. solar tube 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD DP WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE REMOVED FROM DEVICE 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS TO EXISTING RESIDENCES S INDICATES THE LOCATION OF WIRED SMOKE ALARMS GLAZING 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND 600 SUBJECT TO CONFIRMATION UPON SITE MEASURE 13.00° 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR PRIVACY OPTIONS ELECTRICAL AND ENERGY EFFICIENCY 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED INDICATIVE ONLY downpipe to run through deck DOWNPIPES ALL LOCATED DOWNPIPES INDICATIVE ONLY AND DP DP CONFIRMED AT TIME OF ROOFING CONSTRUCTION AND COMPLIANCE DOWNPIPE LOCATIONS ARE SUGGESTED ONLY ROOF DESIGN AND BUILDER TO CONFIRM roof plan NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 16 of 16 DATE: ISSUE NO: RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:100 14 AUG 2019 P -FINAL NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.