19 Viewland Drive Final Renovation Plans Stage 16 · OPW19/0180
Attached to the e-mail Operational Works Application OPW19/0180 - DA Form 1 - Supporting information document - Plans - Plans - Arborist Report - at 19 Viewland Drive Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES 19 viewland drive, noosa heads 4567 lot 8 on RP88535 TIMBER FRAMING AND CONSTRUCTION 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 3075 1200 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK existing 250x150x8mm i beam existing steel beam location from inside blockwork 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 4700 3660.1.2000 roller door DOMESTIC SMOKE ALARMS 6610 7008 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT REGULATION 2016 roller door 3408 75 3718 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM SYSTEMS. 1855 75x75 shs post new point load for steel beam 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD 1600 1090 WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE 1325 REMOVED FROM DEVICE 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND 1215 75 BEDROOMS TO EXISTING RESIDENCES extent of proposed S INDICATES THE LOCATION OF WIRED SMOKE ALARMS 2590 blockwork to match existing (approx) GLAZING 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND SUBJECT TO CONFIRMATION UPON SITE MEASURE 3193 2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT 5790 TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR PRIVACY OPTIONS 6517 ELECTRICAL AND ENERGY EFFICIENCY 3200 1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED 900 INDICATIVE ONLY 2593 DOWNPIPES ALL LOCATED DOWNPIPES INDICATIVE ONLY AND 1200 CONFIRMED AT TIME OF ROOFING CONSTRUCTION AND COMPLIANCE Slab Plan 45 3455 2690 3500 approx location of boulder retaining (stairs and landscaping to be determined on site by owner/builder) slab plan NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: RON O'GRADY BUILDER: MANDY'S DESIGN & DRAFTING SHEET: 15 of 16 DATE: ISSUE NO: RENOVATION EXTENSION PH: 0417 602 074 TBC PH: 0403 481 474 SCALE: 1:100 14 AUG 2019 P -FINAL NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
19 Viewland Drive Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
Final Renovation Plans Stage 16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.