Original source · versioned page text
2014-09-25 Ordinary Meeting Minutes
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
ORDINARY MEETING MINUTES 25 SEPTEMBER 2014
d. all existing effluent disposal areas are wholly located within the lot
they serve and comply with the boundary setback requirements of
the Plumbing and Drainage Act 2002 and associated codes and
requirements;
e. all retaining walls and structures are fully contained within the lot
they retain;
f. any fill, including fill batters, are wholly contained within the subject
site and not on adjacent properties.
House Site Areas
6. Prior to endorsement of the plan of survey by Council, a plan shall be
submitted to Council identifying a building envelope for the house site and
effluent disposal area/s on Lot 2. To address noise, the house site area/s
shall be greater than 80m from the rail corridor, or alternatively,
positioned outside the 65dB(A) 24hr average equivalent A-weighted
sound pressure level AND 87dB(A) single event maximum sound
pressure level contours emanating from rail noise, as identified in an
acoustic assessment prepared by a suitably qualified person and
approved by Council.
ENGINEERING
Site Access and Driveways
7. A sealed access driveway must be provided from Edward Street for the
full length of the proposed access easement. The works must be
undertaken in accordance with an Operational Works approval and must
include in particular:
a. A 3m wide sealed access extending from the end of the current
formation in Edward Street to the property boundary,
b. A 4m wide sealed access for the full length of the proposed access
easement including a 5.5m wide passing bay located between the
Edward Street frontage and the access to Lots 1 and 2,
c. Sealed access driveways to Lots 1 and 2 extending from the edge
of the shared access driveway to the boundary of Lots 1 and 2, and
d. Underground service conduits for all utility services.
Stormwater Drainage
8. The site must be provided with a stormwater drainage system connecting
to a lawful point of discharge. The works must be undertaken in
accordance with an Operational Works approval and must include in
particular:
a. An interallotment drainage system extending from the boundary of
Lot 1 to James Street;
b. the use of gravity stormwater drainage.
Electricity and Telecommunication Services
9. Reticulated electricity and telecommunication services must be provided
to each lot in accordance with an approval for Operational Works and the
standards and requirements of the relevant service provider.
10. Unless otherwise stipulated by telecommunications legislation at the time
of construction, the development must be provided with all necessary
conduits, pits and pipes to accommodate the future connection of optic
fibre technology telecommunications.