Original source · versioned page text
Attachment C - Bushfire attack level report
Bushfire Attack Level Report v1 NCES REF: J000756 Lot 17 on RP903874 – 268 Kinmond Creek Rd, Cootharaba 5.0 AS 3959:2018 BAL ASSESSMENT AS 3959:2018 provides minimum construction requirements for assessable building works in Designated Bushfire Prone Areas. Dwellings (and renovated parts of existing dwellings) in Designated Bushfire Prone Areas must be built to the BAL construction standard relevant to the dwelling as identified by AS 3959:2018. 5.1 Methodology The BAL identified herein has been determined by using the normative procedure described in Appendix B (Method 2) of AS 3959:2018. Table 2 describes the general steps used under AS 3959:2018 to determine the BAL. Table 2 – Methodology Step Clause Procedure 1 2.2.2 Determine the relevant fire danger index. 2 2.2.3 Determine the classified vegetation type(s) 3 2.2.4 Determine the distance of the site from the classified vegetation type(s) 4 2.2.5 Determine the effective slope(s) under the classified vegetation type(s) 5 2.2.6 Determine the BAL from the appropriate table (Flamesol model used). 6 2.2.7 Determine the appropriate construction requirements. Quantitative modelling of the potential bushfire conditions that may be experienced within the Type A Forest vegetation located surrounding the location of the proposed dwelling has been undertaken to identify the BAL acting on the works. The FLAMESOL Minimum Distance calculator has been used to ascertain the BAL dimensions and comprises an AS 3959:2018 Method 2 (Appendix B) based calculator. The following input data was used to determine the BAL based on the conditions observed during the site inspection in January 2021 and the plans presented for assessment (refer to Table 3). Table 3 – Input Data Input Parameter Input Data Fire Danger Index 47 (QFES 2019) Type A Forest – all directions AS 3959 Vegetation Type QFES Vegetation Hazard Classes and Fuel VHC 8.1 Wet Eucalypt tall open forest (combined Loads surface fuels 31 t/ha and 35 t/ha total fuels) North – 10m Distance of classified vegetation from South – 10m building East – 10m Note- The Noosa Plan allows 10m exempt West – 10m clearing for building works on Category 3 Lots North – 1º Upslope Effective slope(s) under the classified South – 12º Downslope vegetation type East – 10º Downslope West – 1º Upslope Flame Width 100m - North, East & West, 45m – South (based on post development (i.e. 10m exempt clearing about © 2021 6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.