Council archive · source document
Application part 3 [As Published] · 142007.1242
Very large file (10.1 MB): the original may take a few minutes to open or download. The page text below is quick to read.
“ Appendix C - Noise & Vibration Construction Stage Environmental Procedures Commercial Development Eenie Creek Road. Revision No: 000 October 2006 2of2 c4. C5. INSPECTION AND MONITORING The following inspection and monitoring program will be conducted at the site. The results of these activities will be documented as they are completed. Activity Frequency Responsibility 1. Inspect the maintenance and servicing |} Bi Monthly records of plant equipment. Project Manager adjacent sites during site activities that are | Project Manager expected to result in noise levels that may exceed performance indicators. 2. Conduct noise monitoring surveys at! As judged by the Project Manager 3. Monitoring of noise in accordance with | On AS1055-1 Acoustics - Description and | more than measurement of environmental noise will | similar noise be undertaken in response to noise | complaint complaints. receipt of 1 Project Manager PERFORMANCE INDICATORS Item Performance Indicator 1. Working Hours 7.00 am to 6.00pm Monday to Saturday, excluding public holidays, except as agreed by Council and suitable measures are implemented to suppress noise emissions. 2. Noise Levels at Construction noise inaudible within a habitable room during: noise sensitive « 6.00pm to 7.00am Monday to Saturday place e Sundays & Public Holidays 3. Noise Noise measured at a “Noise Sensitive Place” Level Monday to Saturday Sundays and public holidays dB(A) Jam-6pm | 6pm- 10pm- Yam-6pm 6pm-10pm | 10pm-9am measured 10pm Jam as Laro-ddj, 65 60 50 65 60 50 1Omins Lavadj, 1Omins 70 65 55 70 65 55 Noise measured at a “Commercial Place” Monday to Saturday Sundays and public holidays Tam— 6pm-10pm | 10pm-7am | 9am-6pm 6pm-10pm | 10pm-9am 6pm. Lato-adj, 70 65 55 70 65 50 10mins La1.adj, 10mins 75 70 60 75 70 60 4, Complaints No complaints received regarding noise. Any complaints regarding noise are to be dealt with immediately and if necessary measures implemented to prevent recurrence. 5. Vibrational Energy Peak Particle Velocity <5 mm/s. Golder Associates 06683025 - 3000(AA)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Application part 3 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 10.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.