07/2125 - Op Works - Bulk Earthworks [As Published] · 142007.2125
(a Douglas Partners Gestechals - Eeviresecd Crewetuctiar Page § Table 3 - Summary of Compaction and CBR Test Results . Optimum Maximum Pit Depth Moisture Swell. CBR No. (m) Description Oe Content | (%) (%) (%) 1 0,5-0.9m Silty Clay Filling ‘1.68 21.2 1.7 40 0.2-0.8m _ Silty Clay Filling 1.61 21.5 27 . 3.0 7.0 COMMENTS 7A Proposed Development Information provided by Bunnings indicates that be the development i is to comprise the construction of a Bunnings Warehouse, comprising a part mas , part metalgc clad, slab-on-ground building with -associated outdoor covered retail areas, as Wal ies driveways andJarge areas of carparking. The site slopes down to the north and north west, and: dup J to. 5m to ye fill and locally upto 10m, including a large. quantity of imported filiais required jorm a level Building platform. Details of ‘ proposed retaining walls, if any, are not known 7.2 Ground Conditions The subsurface conditions, as ed eviouslysi ve teport, generally comprised: . ‘uncontrolled’ c Balen sand ands fravel filling with significant demolition material and some hydrocarbon e@h srt ion nee _*. anold topsoivsi oi of silty'sand orm to stiff clay, up to 0.6m thick; « . Stiff, very stiff SR resi sual clays “encountered: in th iiding area only, ontomely weathered, extremely low and very ‘low strength claystone and'siltston a : 7.3 Site Classification Site classification of foundation soil reactivity in accordance with AS 2870-1996" strictly only: applies to residential footings and not to commercial or industrial buildings. Such classification, however, provides an indication of the propensity of the ground surface to move with seasonal variation in moisture, and has been used (along with general climatic zoning and general éxperience) to assess the potential depth: of seasonal cracking and potential for softening under, soaked conditions. Due to the large depth of uncontrolled filling present, the site would be strictly Class ‘P’ (problem site) requiring design by engineering principles (i.e. prescriptive AS2870 designs would not apply for a house). The shrink-swell index values obtained in the laboratory testing were input into DP’s in-house program ‘REACTIVE’, to calculate the characteristic surface movement value (y,) in general accordance with AS 2870. It should be noted ‘that AS 2870 provides recommended values of change in suction (Au) and depth of suction (H,):for major and-regional centres: throughout Australia. Based on previous experience i inthe general area and on. published’ data by Fox’, relating climatic ' 24s 2870-1996 Australian Standard “Residential Slabs and Footings - Construction’ Standards Association of Australia, ? Fox E, “A Climate-Based Design Depth of Moisture Change Map of Queensland and the Use of Such Maps to Classify Sites Under AS 2870 19967 Australian Geomechanics, Vol 35, No 4, December 2000. Report on Geotechnical Investigation . Project 33984 Proposed Bunnings Warehause, Eumundi- ‘Noosa Road, Noosaville . 16 August 2006
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2125 - Op Works - Bulk Earthworks [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.