Council archive · source document
07/2125 - Op Works - Bulk Earthworks [As Published] · 142007.2125
€)) Dougias Partners
Gusirsteis-Exckvonre-Creestver .
Page 6
conditions to suction, a value: of 1.2 pF was .adopted for ‘Au and 1.5m for H, in the ‘REACTIVE
calculations. A cracking depth of 0.5m was used. in the analysis, based on 0.33Hs. /
The results of the analysis indicates that the shrink swell: movements in response to seasonal
“moisture variation are.estimate to be:10imm to 20mm,.consistent.with a Class ‘S’ slightly reactive
site.
As mentioned previously, whilst site classification in accordance with AS 2870 strictly only applies to
- residential and not industrial structures, it serves to indicate that care is required in design,
particularly regarding the use of brittle materials such as brickwork, blockwork. and tiles. It is
important that adequate articulation jointing is allowed tor in design, that adequate.site maintenance
is carried out in accordance with BTF 18°, and that all works are designed to minimise soil moisture
content change.
It should be noted that any proposed cut and fill earthworks Thay’ result in the building being partly
founded ori natural clay and: partly on either cla As) imported engineered filling: It is recommended
that structures straddling the cut to fill boundary‘of, the proposed plattorm be founded in materials of
similar strength and compressibility, unless adequa e articulation and‘joint detailing is allowed for in
the structure, to accommodate potentialtdifferential "S6ttléments. Comments on settlement of bulk
filling later in this report should.also be noted design.
7.4 Excavatability
riet ulk excavation to form the. building pad as well
recompaction of existing uncontrolled fill, as well .as
as possible excavati 1 attic
iontot fo tation 5, pavements and underground services.
localised excavations {
Based on the conditions’ encount®red to the depth of the test bores, it is estimated that bulk
excavation may be undertaken by ‘tedium “sized excavation plant, such as a 25-30t hydraulic
excavator, for cut in existing filyand Very stiff and hard and weathered claystone and siltstone. of
extremely low or very low strenigthé Where claystone and siltstone rock stronger than very low
strength is encountered (if anywhere), excavation rates will be slower and may require the use of a
. ripping tyne or pneumatic rock breaking tools, particularly in confined excavations.
It should be-recognised that the above éxcavatability estimates are based on materials encountered
at test locations only and that conditions may prove more difficult (or easier) for excavatability
between and beyond these test locations.’
7.5 Re-Use of Excavated Materials and Workability
From the results of the test bores, it is concluded that the majority of the clay and existing clean
“uncontrolled” filling materials won from excavation at the site will generally be suitable for re-use as
bulk filling. Such re-use is contingent-upon particle size distribution being controlled along with
moisture content, and upon minimum: placement and compaction’ requirements being met, all as
indicated in this report. Sorting ‘of the fill containing demolition material (typically encountered in the
areas of deeper fill) will be required to remove potentially deleterious material or material that will
inhibit effective compaction, such as timber, tree roots and other organic matter, particles over
250mm that cannot be broken down or crushed .and larger metal objects. Existing bricks, blocks and
° BTF 18 “Foundation Maintenance and Footing Performance: A Homeowner's Guide", CSIRO 2003.
” “Report on Geotechnical investigation " Project 33984
. Proposed Bunnings Warehouse, Eumundi-Noosa Road, Noosaville. not . _ 16 August 2006
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records