Original source · versioned page text
Acoustic report
Attached to the e-mail Response to Information Request - MCU18/0120, RAL18/0013, OPW18/0197.
Hass Holdings atf The Quasar Trust Environmental Noise Level Study for Proposed Industrial Business Type 2 (Production, Alteration, Repackaging and Repairing), 5 Taylor Court, Cooroy Page 12 of 17 APPENDIX A: AMBIENT NOISE LEVEL MEASUREMENTS Measurement Equipment The following equipment was used to conduct the ambient noise level study at Monitoring Location A: • Bruel and Kjaer Type 2260I Modular Precision Sound Analyzer – Observer – Serial No. 2409372, with Type BZ 7220 Software and Prepolarised free-field ½” microphone, Type 4189, Serial No. 2395446; • Bruel and Kjaer Type 3592 outdoor microphone kit, including Type UA1404 outdoor microphone; • Bruel and Kjaer Type AO 0442 ten metre microphone extension cable; and • Bruel and Kjaer Type 4231 Sound Level Calibrator, Serial No. 2292746. All of the above equipment is Type 1 in accordance with the requirements of Australian Standard AS 1259-1990, Acoustics – Sound Level Meters, as required by Australian Standard AS 1055.1-1997. Measurement Equipment Settings The above equipment was used with the following settings: • Detector: RMS • Time Weighting: FAST • Frequency Weighting: A • Sound Incidence: FRONTAL • Microphone sensitivity: -27.3 dB • Range: 10-90 dB. Calibration The sound level meter was calibrated to the required value of 93.8 dB at 1000 Hz immediately before and after the noise level measurements were conducted. At no time was an adjustment of more than 0.5 dB required. This complies with the requirements of the Australian Standard. Monitoring Location Monitoring Location A was on the front (eastern) boundary of the private residential property at 72 Ferrells Road, Cooroy with the microphone elevated 1.8 metres above ground level. The permission of the owner to locate the noise logger on their property is appreciated and acknowledged. Ambient noise levels at this location would be representative of the ambient noise levels at all of the closest residences to the subject site with a similar separation distance from the Bruce Highway. Refer Figure 1 for further details. Atmospheric Conditions Throughout the ambient noise level study, atmospheric conditions complied with the requirements of the Australian Standard. David Moore & Associates Pty Ltd Our reference: R18062/D3342/Rev.0/25.09.18
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original