Original source · versioned page text
Acoustic report
Attached to the e-mail Response to Information Request - MCU18/0120, RAL18/0013, OPW18/0197.
Hass Holdings atf The Quasar Trust Environmental Noise Level Study for Proposed Industrial Business Type 2 (Production, Alteration, Repackaging and Repairing), 5 Taylor Court, Cooroy Page 13 of 17 APPENDIX B: RESULTS OF AMBIENT NOISE MEASUREMENTS Instrument: 2260 Application: BZ7219 version 1.1 Start Time: 22/04/2013 10:57:17 AM End Time: 29/04/2013 11:51:19 AM Elapsed Time: 168:54:02 Bandwidth: 1/3 Octave Peaks Over: 140.0 dB Range: 11.3-91.3 dB Time Frequency Broad-band measurements: SFI AC Broad-band statistics: F A Octave measurements: F L Logging Log Rate: 0:15:00 Broadband Parameters: All Spectrum Parameters: All Instrument Serial Number: 2409372 Microphone Serial Number: 2395446 Input: Microphone Windscreen Correction: None S. I. Correction: Frontal Calibration Time: 22/04/2013 10:55:18 AM Calibration Level: 94.0 dB Sensitivity: -27.3 dB ZF0023: Not used David Moore & Associates Pty Ltd Our reference: R18062/D3342/Rev.0/25.09.18