Skip to the record
The only place to find full transcripts.

Original source · versioned page text

Attachment E - Previous Extension to Currency Period 5-10-18

of 8

Page text shows just the words. Original shows the document exactly as it was published.

Noosa Council documents




                      (b)     The retention of the existing overland flowpath that conveys stormwater runoff from the
                              adjoining property (Lot 26 SP151406) through proposed Lot 103. The flows must be
                              contained and conveyed wholly within a combined drainage solution consisting of
                              underground drainage, capable of accommodating flows up to a Q10 event, and a
                              landscaped and suitably stabilised (rock lined or other engineered alternative) open
                              drain. The design of the drain must be sufficient to include all design storm events up
                              to and including the 1%AEP event of critical duration. Design calculations (that include
                              at a minimum depth of flow and velocity) and certification by a suitably qualified RPEQ
                              demonstrating the above must be submitted as part of the operational works
                              application
                      (c)     Additional elements in the design of the open drain (localised bunding etc) that allows
                              stormwater flows from the minor storm event to enter the existing piped system and
                              ensure that velocities (generated in both the major and minor events) are in accordance
                              with the safety guidelines recommended in QUDM.
                      Electricity and Telecommunication Services
               10.    Underground reticulated electricity and telecommunication services must be provided to
                      each lot in accordance with an approval for Operational Works and the standards and
                      requirements of the relevant service provider.
               11.    Unless otherwise stipulated by telecommunications legislation at the time of construction, the
                      development must be provided with all necessary conduits, pits and pipes to accommodate
                      the future connection of optic fibre technology telecommunications.
               12.    Certification must be submitted to Council from all relevant service providers which certifies
                      that the development has met the requirements of this Decision Notice and all applicable
                      legislation at the time of construction.
                      Easements
               13.    A drainage easement must be created within proposed Lot 103. The easement must be:
                      (a) Of sufficient width (approximately 4.5m) to encompass all elements of the combined
                            underground pipe and open drain solution (underground pipe (Q10 flows), batters,
                            bunds, etc. and a 1.5m maintenance track),
                      (b) In favour of Lot 26 SP151406 to connect to a legal point of discharge as defined in
                            QUDM.
                      (c)     Alignment of the underground pipe, open drain, and easement is to be determined
                              through operational works application (as per condition 9(b) above).
               14.    A drainage easement must be created within proposed Lot 101. The easement must be:
                      (a) In favour of Lot 26 SP151406 and proposed Lot 103,
                      (b)     Centrally located over the existing piped drainage system connecting proposed Lot 103
                              and Lot 26 SP151406 to the existing stormwater discharge point in Gateway Drive.
               15.    Unless otherwise agreed in writing by the relevant service provider, any public or third party
                      infrastructure located on the subject site must be placed within an easement registered
                      against the title of the property.
               16.    All easements must be designed in accordance with the planning scheme and granted at no
                      cost to the Grantee. Where the Grantee is Council or a service authority, the easement
                      documentation must be in accordance with the Grantee’s standard easement terms. Draft
                      easement documentation must be submitted to Council for endorsement.
               17.    All works must be kept clear of any existing or proposed easements on the subject land,
                      unless agreed otherwise in writing by the Grantee.




                                                                                                          Page 3 of 8
Document Set ID: 20709606
Version: 4, Version Date: 05/10/2018                                                               Print Date: 5 October 2018, 11:29 AM
Log in to download the original file

Attachment E - Previous Extension to Currency Period 5-10-18.pdf · 217 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.