Appendix B - SWMP, Flood Cert & Form 15
Figure 4.4 – Typical Tank node configuration
The tanks will be plumbed for internal reuse which has been modelled in accordance with
the Water by Design MUSIC Modelling guidelines. The reuse demands have been
determined as follows:
- Internal Reuse
o All homes are assumed to be fitted with full water saving devices,
26L/Person/day for laundry
21L/Person/day for toilets
o 3-bedroom townhouses:
2.3 persons per unit
2.3 * 47L = 108.1L/day/unit
4.2.1.1. Pit Inserts
The grated inlet pits in the driveway are to be fitted with Ocean Protect Ocean Guard Litter
baskets (or approved equivalent). The inserts are modelled using generic treatment nodes,
with a high flow bypass of 20L/s per insert and concentration-based capture efficiency set
in accordance with the manufacturers specifications shown below in Figure 4.5 to Figure
4.8. Refer to Appendix B Ocean Protect Ocean Guard Litter Basket for further details on
the devices.