37. The existing 300mm stormwater drainage pipeline on the site shall be inspected by closed
circuit television (CCTV) prior to the commencement of the civil works on the site, any existing
damage or blockage shall be rectified by the developer prior to the construction of the
driveway. Also, following satisfactory completion of the construction works all new stormwater
pipelines that will be a Council’s asset and stormwater inter-allotment drainage shall be
inspected by CCTV.
CCTV inspections will be carried out by Council's CCTV contractor and arranged by Council.
The developer will be responsible for the full cost of CCTV inspections, including any
additional inspection necessary following defect identification and rectification. This charge is
payable prior to the issue of Operational Works approval and will be determined on the unit
rate basis current at the time of approval.
Service Easements on Lot 85 M11112 (Stormwater)
38. A registered easement shall be required over any stormwater drainage pipes or overland flow
paths within the site that convey stormwater from a Council road. The easement shall be in
favour of Council, be a minimum of 3 metres wide within the site and be located adjacent to
the northern boundary of the subject site.
The Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in writing that
the Title Deed and the easement documents will be lodged at the Land Titles Office and any
additional Titles Office forms or requisitions requiring the consent of Council will be attended to
promptly. A duly executed copy of the easement shall be submitted to Council for perusal prior
to the use commencing. Any changes required by Council’s Solicitor must be corrected
immediately.
39. No building or other structure shall be constructed or encroach over an easement.
Earthworks
40. All earthworks (filling or excavation) required on site shall be carried out in accordance with
Council’s Planning Scheme Policy PSP5 – Engineering Design Standards. Filling on the site
shall not cause any additional ponding of water on any adjoining lands or the blockage of, or
interference with, any natural watercourses.
41. Any imported fill to the site may only be from a site licensed with The Environmental Protection
Agency or from a site for which a Development Permit for Operational Works has been issued
approving the export of fill.
42. Earthworks carried out on site shall not affect the structural integrity of any of the existing
fences or structures that border the development site. Fences that are affected shall be
replaced prior to the Building Certifier issuing the Certificate of Classification. In this regard
any fences to be replaced shall be clearly shown on the plans submitted for Operational
Works approval.
Erosion and Sediment Control
43. Any person acting on this permit shall prevent erosion and sediment export from leaving the
site. Site control measures such as silt fencing, controlled gravel access to the site and
controlled disposal of waste, will be necessary.
In this regard plans detailing the methods of controlling erosion and sediment are required to
be submitted to the Council for approval prior to obtaining a Development Permit for
Operational Works.
General Engineering Requirements
44. A suitably qualified Registered Professional Engineer shall prepare engineering drawings and
specifications for all engineering works that will become Council infrastructure, which shall be
submitted in conjunction with an application for a Development Permit for Operational Works.
In this regard a DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be
submitted in conjunction with any application for Operational Works.
Page 7 of 17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SPA Decision Notice - 010.2010.00000812.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 295 KB (small file)
- File type
No other editions are linked here.