                                                                                            2010/812




45.   Digital detailed designs including drawings, calculations, specifications and a schedule of
      works shall be submitted with any application for a Development Permit for Operational Works
      in respect of roadworks and stormwater drainage works. The design shall be in accordance
      with Council’s Planning Scheme Policy PSP05 – Engineering Design Standards – Roads,
      Drainage and Earthworks. To avoid conflict with underground pipes or services, all existing
      and proposed services required by the development shall be shown on the plans.
46.   To facilitate production of As Constructed drawings it is suggested that all design drawings are
      submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the
      use of ADAC are available at www.adac.com.au).
47.   Any damage caused to any public utility during the course of construction shall be repaired to
      Council’s standards and at no cost to Council.
48.   Any alteration of any public utility or other facilities necessitated by the development of the
      land or associated construction works external to the site shall be at no cost to Council.
49.   The transportation of all materials to and from the site shall be undertaken in a manner such
      that no particle matter escapes onto a public road. All vehicles carrying materials either to or
      from the site shall be covered to prevent materials including dust being windblown from the
      vehicle.
50.   As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer
      for design intent, and a Licensed Surveyor shall certify the cadastre and the location, level and
      type of all services and structures. All of which shall be submitted to Council for checking and
      for Council’s records.
      The data must fully detail levels for all engineering works including but not limited to drainage
      structures, finished ground levels and pavement surface levels. The data shall be submitted in
      the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC
      are available at www.adac.com.au). Approval of works shall not be granted until all As
      Constructed information has been supplied and accepted by Council.
Unity Water
51.   Reticulated water supply and sewerage must be provided to the development.
52.   Separate 25mm PE water services must be installed to a common lot boundary with
      independent meters installed outside the boundary of the lot in accordance with Sunshine
      Coast water standard drawing SCW 361. Meters must be “Elster” PSM 50100/39 (dual
      check).
53.   The sewer inspection opening must be located a minimum of 1.0 metre from any structure and
      be raised to the finished surface level of the site. If located within the paved driveway area the
      inspection opening must be finished with a brass cap.
54.   Storm water retention systems and gross pollutant traps must maintain a minimum clearance
      of 1.5 metres from Council water supply and sewerage infrastructure .
55.   Landscape planting within 1.5 metres of Council sewerage infrastructure must be Council
      approved varieties and low growing when mature.
56.   Construction works undertaken in the vicinity of Council water supply or sewerage
      infrastructure must not adversely affect the integrity of the infrastructure. All costs associated
      with repair, replacement or alteration of infrastructure must be met by the applicant.




                                                                                            Page 8 of 17

Used in these records

About this file

File size
295 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SPA Decision Notice - 010.2010.00000812.001 [As Published].pdf · 295 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.