25. Conduits and kerb markers shall be installed for all necessary service crossings of roads
--to-eouncil’s satisfaction:----;A.n-"As-eonstructe-d" pian-shnwing the-locations of-the-conduits----
.
_shall be submittedlo Council.prior to acceptance.of the works "On Maintenance".
26. All sag points in trenches excavated for the installation of underground infrastructure
shall be drained to a drainage pit.
27. Subsoil drains shall be used to ensure trenches are not dammed by pits, manholes or
other structures, and drained appropriately.
Any alteration of a public utility or other facility necessitated by the development of the
land or associated construction works either internal or external to the site shall be at no
cost to Council.
Easements
28. Prior to Council approval of the Plan of Survey, a duly executed CQPY of any required
Grant of Easement for services shall be .submitted to Council for perusal.
Any changes required by Council’s Solicitor shall be attended to prior to endorsing the
.. .. -
- .
Plan of Survey.
\ Any necessary Titles Office forms requiring the consent of Council is to be submitted
prior to the endorsing of the Plan of Survey.
29. Prior to the approval of the Plan of Survey, the Applicant’s Solicitor shall give Council’s
Solicitor an appropriate undertaking in writing that in conjunction with lodgement of the
Plan of Survey at the Land Titles Office, the Title Deed and the easement documents
.
will also belodged and any additional Titles Office forms or requisitions requiring the
consent of Council being attended to forthwith.
’\
.
30. Legal documentation presented to Council as a requirement of this Development Permit
shall be submitted in the correct form, with the fees prescribed in Council’s adopted fee
schedule, in conjunction with the lodgement of the plan of subdivision for Council
approval.
Electricity and Telecommunications
31. An underground electricity service shall be provided to each lot if not already provided.
In this regard, an approved ENERGEX Electrical Design Consultant shall work in
conjunction with Council’s Manager Works Support to prepare detailed designs of the
-
electrical proposal.
The detailed deigns shall then be submitted to ENERGEX for approval and a copy of
their approval submitted to Council in conjunction with a "Certificate of Electricity Supply
for Proposed Subdivisions" (prepared by an approved ENERGEX Electrical Design
Consultant) prior to Council endorsing the Plan of Survey.
Any agreement with ENERGEX or an approved ENERGEX Electrical Design Consultant
shall be wholly at the applicant’s expense and shall not entail a financial encumbrance
on future purchasers of the proposed lots.
Street lighting and pathway lighting throughout the subdivision shall be provided in
accordance with Council’s Engineering Design Standards, section 11.3.3 and to the
satisfaction of Council.
32. The requirements for TELECOMMUNICATION services shall be satisfied in relation to
any existing services that currently traverse the site and for the provision of new
telephone services to the proposed lots. In this regard written confirmation from an
approved telecommunication agency shall be submitted to the Council prior to Council
endorsing the Plan of Survey.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request change to an approval 152004.240078.4Related documentApplication case desk ↗
About this file
- File size
- 13.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.