1. INTRODUCTION

D M Hayes Consulting has been commissioned by Oak Investment Holding to
provide traffic engineering advice for the car parking arrangements for a proposed
apartment development at Sunshine Beach. This report has been produced to assess
the number of car parking spaces, its compliance with Australian Standards and The
Noosa Plan and manoeuvreability within the site.

2. PROPOSED DEVELOPMENT

The proposed development is for 5 three bedroom apartments at Elanda Street,
Sunshine Beach. The proposal will be assessed under the requirements of The Noosa
Plan as Type 4 Conventional Residential Land Use.

A copy of the proposed plans has been provided by Ian Gorton Design and is attached
in Appendix A.

2.1 Access

Access to the proposed development will be from Elanda Street. A 3.5m
access driveway will be provided into the basement car park. Secure garage
doors for 10 parking spaces will be provided, in addition to two open parking
spaces.

3. CAR PARKING REQUIREMENTS

An assessment of car parking has been undertaken in accordance with The Noosa
Plan and the Australian Standards for Parking Facilities AS2890.1.

3.1 Requirements of The Noosa Plan

According to The Noosa Plan Part 14 — Driveways and Parking Code the
vehicle parking requirements for Type 4 Conventional Use indicate, 1 covered
space per dwelling unit and 1 space per 2 dwelling units or part thereof, which
may be located in tandem.

3.2 Australian Standards AS2890 Requirements

The requirements for parking are outlined in AS2890.1:2004. The proposed
development requires facilities for long-term parking identified as User Class
1A (residential parking). Dimensions for car parking are outlined in Figure
2.2 of AS2890.1. Minimum requirements for 90 degree angle parking bays
include a width of 2.4m, length of 5.4m and aisle width of 5.8m. The aisle
width required is to allow three-point entry and exit into 90 degree parking
spaces only as outlined in Table 1.1 of AS2890.1.

Car Parking Assessment — Elanda Street, Sunshine Beach
For Oak Investment Holding P/L

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2174 - Traffic report [As Published].pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.