07/2174 - Traffic report [As Published] · 132007.2174

of 14

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

DM Hayes
Traffic Engineering Consultant

 

4. PROPOSED CAR PARKING ARRANGEMENTS

Parking has been provided within the site from an access driveway located at the
south-eastern boundary of the property. Provision for 10 secure parking spaces has
been accommodated with two open parking spaces. Refer to Appendix A for layout
of proposed parking arrangements.

4.1. Compliance with The Noosa Plan Requirements

The development comprises of 5 three bedroom units on two levels with
parking provided within the basement. The proposed development has made
provision for 10 secure parking spaces, in addition 2 open parking spaces have
also been provided. The minimum number of spaces required by The Noosa
Plan for this development is 8 parking spaces. Therefore the proposed
development complies with the requirements of The Noosa Plan.

4.2 Compliance with Australian Standards AS2890

The parking arrangements have also been assessed against AS2890.1:2004.
Clause 2.5.3 (c) includes requirements for grades for private or residential
driveways (other than domestic). Ramps up to 20m long shall be 1 in 4 (25%)
maximum. The proposed ramp into the basement car park is 1 in 4.9
complying with this requirement.

Clause 3.3 includes requirements for gradients of access driveways. The
grade for the access driveway from the road frontage (kerb) to the property
boundary is a maximum of | in 20 (5%). The proposed access meets the
requirements for access driveways.

Clause 5.4 includes requirements for the design of enclosed garages. The
parking spaces shall be 2.4m wide with an additional 300mm clearance on the
outside of each outer space. The door with must be 4.8m for two parking
spaces. Apron width shall be 5.8m. The garages have been designed to
comply with this requirement.

Clause 3.2.2 includes width requirements for access driveways and connecting
roadways. The requirements for the proposed land use are recommended for
case-by-case basis and assessment should be made applicable to the subject
site. In regard to width and passing opportunity, due consideration has been
given to traffic generated from the site and the proposed number of trips. The
proposal includes 5 apartments with three bedrooms. Traffic generation rates
recommended in the RTA Guide to Traffic Generating Developments for
units/apartments with three or more bedrooms, indicate a weekday peak hour
traffic rate of 0.5-0.65 trips per dwelling. This results in 3 vehicle trips during
the peak hour. Given the proposed residential use for this development and
the traffic generation, it is unlikely that two vehicles will be accessing the
basement at any one time. Clause 3.2.2 states;

“As a guide, 30 or more movements in a peak hour (in and out
combined) would usually require provision for two vehicles to pass

Car Parking Assessment — Elanda Street, Sunshine Beach
For Oak Investment Holding P/L

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2174 - Traffic report [As Published].pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.