Original source · versioned page text
Noise and Air Quality Impact Assessment W D Milligan 31 July 2014
Attached to the e-mail MCU12/0184 - Covering email for Noise & Air Quality Impact Assessment & Traffic Engineering Report (Separately registered). A Link to the Traffic Survey video is in email..
MWA Environmental
Consideration has also been given to the potential for catch-out activities and feed
deliveries to cause sleep disturbance if these activities occur at night. The adopted
sleep disturbance criterion is an Lmax noise level of 45 dB(A) within a bedroom.
Considering a noise attenuation of 7 dB(A) through an open window1 this relates to
an external Lmax criterion on 52 dB(A) at surrounding residential dwellings.
The adopted design noise criteria for the various activities and periods of the day
which are specified in Table 2 below were calculated in accordance with the above
methodology.
Table 2: Adopted Design Noise Criteria – dB(A)
ADOPTED
ACTIVITIES ADOPTED CRITERIA PERIOD NOISE LIMIT
BACKGROUND
Queensland LA90
7am to 6pm 39 dB(A)
Environmental 39 dB(A)
Background
Protection (Noise)
+ 0 dB(A)
Ventilation Policy 2008 LA90
assessed as 6pm to 10pm 36 dB(A)
Fans 'Controlling 36 dB(A)
L90 from the
Background Creep':
activity
(a) for noise that is LA90
continuous noise 10pm to 7am 34 dB(A)
34 dB(A)
Queensland LAeq
7am to 6pm 39 dB(A)
Environmental 44 dB(A)
Background
Protection (Noise)
+ 5 dB(A)
Policy 2008 LAeq
assessed as 6pm to 10pm 36 dB(A)
Catch-out 'Controlling 40 dB(A)
Leq from the
Activities & Background Creep':
activity
Feed Deliveries (b) for noise that LAeq
varies over time 10pm to 7am 34 dB(A)
38 dB(A)
LAmax
Sleep Disturbance 10pm to 7am n/a
52 dB(A)
1 AS3671 states approximately 10 dB(A) noise reduction through a façade with 10% open area. Thus
approximately 7 dB(A) noise reduction through a façade with 20% open area. A typical 1200x1800
sliding window relates to approximately 10% open area. A large 2100x2300 sliding glass door
represents approximately 20% open area. Thus, 7dB(A) noise reduction is conservatively adopted
based upon a large sliding glass door in the affected façade. Openings larger than 20% open area are
unlikely to be necessary for ventilation.
Ridgewood 12-002 7 31 July 2014
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.