Original source · versioned page text
Noise and Air Quality Impact Assessment W D Milligan 31 July 2014
Attached to the e-mail MCU12/0184 - Covering email for Noise & Air Quality Impact Assessment & Traffic Engineering Report (Separately registered). A Link to the Traffic Survey video is in email..
MWA Environmental
Table 4: Ventilation Fan Sound Power Level Spectra – dB(A)
SOUND POWER LEVEL SPECTRA - dB(A) AP
SOURCE
31Hz 63Hz 125Hz 250Hz 500Hz 1kHz 2kHz 4kHz 8kHz dB(A)
Ventilation Fan
61.7 74.1 76.8 79.6 86.8 87.4 84.0 76.7 68.3 91.8
(per fan)
Source noise levels for catch-out activities (i.e. forklifts, trucks) and feed
deliveries (i.e. feed transfer blower, truck) were taken from previous
measurements undertaken by MWA Environmental at similar facilities.
The modelled source sound power levels are summarised in Attachment 3.
2.3.3 RESULTS OF NOISE MODELLING
The results of the SoundPLAN 7.3 modelling are provided in Attachment 4 as
contours of predicted resultant noise levels on an aerial photograph base.
The predicted resultant noise levels at the nearest residential dwellings locations
(refer to Figure 3) are summarised in Table 5 below for the ‘continuous noise
sources’ (ventilation fans) and Table 6 below for the ‘intermittent noise sources’
(catch-out activities and feed deliveries).
Ridgewood 12-002 10 31 July 2014
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.