Noise and Air Quality Impact Assessment W D Milligan 31 July 2014
Attached to the e-mail MCU12/0184 - Covering email for Noise & Air Quality Impact Assessment & Traffic Engineering Report (Separately registered). A Link to the Traffic Survey video is in email..
MWA Environmental
3.4 ODOUR MODELLING RESULTS
Plots of the model-predicted 99.5th percentile 1 hour average odour concentrations
over the model domain are included in Attachment 8.
The model-predicted 99.5th percentile 1 hour average odour concentrations at the
representative surrounding residences (R1 to R28, refer Figure 3) are summarised in
Table 7 below.
Table 7: Model-Predicted 99.5th Percentile Odour Concentrations
1 HOUR AVERAGE
99.5th PERCENTILE
RECEPTOR
ODOUR
CONCENTRATION (OU)
R1 1.2
R2 0.6
R3 0.6
R4 1.1
R5 0.9
R6 1.2
R7 0.8
R8 1.5
R9 1.4
R10 0.8
R11 1.9
R12 0.9
R13 0.5
R14 0.4
R15 0.4
R16 0.7
R17 0.6
R18 0.5
R19 0.6
R20 0.6
R21 0.8
R22 0.5
R23 0.4
R24 0.4
R25 0.5
R26 0.4
R27 0.5
R28 1.2
The results of the modelling indicate that the proposed eight shed poultry farm can
operate in compliance with the relevant 2.5 Odour Units 1 hour average 99.5th
percentile odour amenity criterion subject to the implementation of best-practice farm
management practices.
Ridgewood 12-002 20 31 July 2014
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.