8. Demonstrate that vehicles can enter, manoeuvre throughout the site, park on
site, and leave the site without scraping and/or bottoming. This shall be
undertaken for all types of vehicles expected to enter the site, such as standard
cars, maintenance vans, and emergency vehicles (ambulance) with consideration
given to the height of such vehicles and the headroom required under the
building. Plans of the driveway and driveway profiles need to extend from the
actual David Low Way road into the site, and not just within the bounds of the
site.
9. Illustrate on the proposal plans that suitable sight distances can be achieved from
the proposed access driveway to pedestrians on the pathway network and to
vehicles on the David Low Way based on the 85-percentile design speed of the
David Low Way, not the sign posted speed limit. In this regard a design speed of
70km/h would be more realistic and consideration should also be given to
existing vegetation and/or proposed vegetation that may restrict these sight lines.
10. Illustrate on the proposal plans all “end of trip facilities”, such as bicycle storage
lockers for staff, bicycle storage areas for customers, showers, change rooms,
seating areas, drinking fountains, etc.
11. Demonstrate that the site can be drained without the use of pumps in accordance
with Specific Outcome O17 of Table 14-46 of the Driveways & Carparking Code.
12. Demonstrate that the site can be developed with no net increase in runoff from
the site for storm events up to a 1 in 100 year Average Recurrence Interval. In
this regard the stormwater drainage system designed for the site will need to
incorporate an adequate detention system (holding tanks) to retain these flows
which can be utilised for irrigation, toilet flushing, hose down of paved surfaces,
and ground water recharging.
The present proposal to add these flows into the existing drainage system in the
David Low Way is not supported.
13. Illustrate on the proposal plans the location of the electrical substation and the
location of the fire hydrant booster boxes that are likely to be required in order to
serve the proposed development, with consideration given to how maintenance
and/or emergency vehicle access to these services will be obtained.
14. Demonstrate how the various vegetation and landscaping treatments proposed
on site, such as large trees etc will be retained (and or new trees established)
given the shear size of the buildings and basement carparking areas proposed
and the structural elements required to support such structures, i.e. concrete
retaining walls built to the boundary and concrete carparking slabs leave little
room for plants and their root systems. In this regard the drip line of all trees and
vegetation proposed on site should be kept free of hard surfaces based on the
mature (fully grown) tree size, not the size when planted.
15. It is noted that a fence is planned to be provided along the southern boundary of
the site to reduce noise levels, however no details of this fence have been
provided to illustrate the type of material that will be used to construct it, nor its
height in relation to the existing residential building to the south and existing
windows.
Award Winner - Australian Clean Beach
Challenge 2004 Litter Prevention
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Request for Further Information - 010.2006.00002689.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 25 KB (small file)
- File type
No other editions are linked here.