8.      Demonstrate that vehicles can enter, manoeuvre throughout the site, park on
        site, and leave the site without scraping and/or bottoming. This shall be
        undertaken for all types of vehicles expected to enter the site, such as standard
        cars, maintenance vans, and emergency vehicles (ambulance) with consideration
        given to the height of such vehicles and the headroom required under the
        building. Plans of the driveway and driveway profiles need to extend from the
        actual David Low Way road into the site, and not just within the bounds of the
        site.

9.      Illustrate on the proposal plans that suitable sight distances can be achieved from
        the proposed access driveway to pedestrians on the pathway network and to
        vehicles on the David Low Way based on the 85-percentile design speed of the
        David Low Way, not the sign posted speed limit. In this regard a design speed of
        70km/h would be more realistic and consideration should also be given to
        existing vegetation and/or proposed vegetation that may restrict these sight lines.

10.     Illustrate on the proposal plans all “end of trip facilities”, such as bicycle storage
        lockers for staff, bicycle storage areas for customers, showers, change rooms,
        seating areas, drinking fountains, etc.

11.     Demonstrate that the site can be drained without the use of pumps in accordance
        with Specific Outcome O17 of Table 14-46 of the Driveways & Carparking Code.

12.     Demonstrate that the site can be developed with no net increase in runoff from
        the site for storm events up to a 1 in 100 year Average Recurrence Interval. In
        this regard the stormwater drainage system designed for the site will need to
        incorporate an adequate detention system (holding tanks) to retain these flows
        which can be utilised for irrigation, toilet flushing, hose down of paved surfaces,
        and ground water recharging.
        The present proposal to add these flows into the existing drainage system in the
        David Low Way is not supported.

13.     Illustrate on the proposal plans the location of the electrical substation and the
        location of the fire hydrant booster boxes that are likely to be required in order to
        serve the proposed development, with consideration given to how maintenance
        and/or emergency vehicle access to these services will be obtained.

14.     Demonstrate how the various vegetation and landscaping treatments proposed
        on site, such as large trees etc will be retained (and or new trees established)
        given the shear size of the buildings and basement carparking areas proposed
        and the structural elements required to support such structures, i.e. concrete
        retaining walls built to the boundary and concrete carparking slabs leave little
        room for plants and their root systems. In this regard the drip line of all trees and
        vegetation proposed on site should be kept free of hard surfaces based on the
        mature (fully grown) tree size, not the size when planted.

15.     It is noted that a fence is planned to be provided along the southern boundary of
        the site to reduce noise levels, however no details of this fence have been
        provided to illustrate the type of material that will be used to construct it, nor its
        height in relation to the existing residential building to the south and existing
        windows.




     Award Winner - Australian Clean Beach
       Challenge 2004 Litter Prevention

Used in these records

About this file

File size
25 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Request for Further Information - 010.2006.00002689.001 [As Published].pdf · 25 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.