25.048_The Peninsula_Issue B_21Aug25(3)(1)(1)Building Design
drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: DAVID FENECH
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
Address: No. 18 THE PENINSULA, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 444 ON RP856191 DRAWING NAME REV DATE
COVER SHEET B 21/08/25
A3
DESIGNER PROJECT NO
SD KUNKEL 25.048
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
property details
No. 18 The Peninsula
Noosaville QLD 4566
41.500m 107°20'0" Projected boundary Noosa Shire Council
Locality - Noosaville
1500 water allocation boundary Lot 444 on RP856191
Site Area - 789m²
peninsula
Existing jetty to water allocation area Zone - Low Density Residential
be removed Precinct - Nil
Boat lifting Overlays - Acid Sulphate Soils
10075
10075
- Flood Hazard
197°20'0"
device (8.5x3.5m)
17°20'0"
- Coastal Hazard
canal
10000 from revetment wall
proposed
jetty
19.000m
19.000m
8925
the
Floating cube
7425
Existing dock (2.5x5.0m)
revetment wall
1500 water allocation boundary
1500
41.500m 107°20'0" Projected boundary
15000
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 DAVID FENECH NEW JETTY SITE PLAN 01 B 25.048 A3
NORT
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
No. 18 THE PENINSULA, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
H
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
B 21/08/25 SDK CONSTRUCTION ISSUE Lot 444 ON RP856191 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
notes
1. Contractor to confirm exact siting and orientation
200x50x3mm aluminium 2/152x63x6mm structural prior to construction setout.
floor joists @ 450mm crs max. 'c' channel headstocks per pile
2. All building setout & confirmation of setbacks &
10000 750 2830 2840 2830 750 height to be carried out by a Licensed Surveyor.
3. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
750
750
Do not fix jetty
jetty
1500
4. Levels & services locations to be confirmed prior to
to revetment wall
750
construction.
5. Termite protection to be provided in accordance with
Do not fix jetty Joists to butt into headstocks
2750
clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
2000l rigid handrail to Contractor to provide protection information for building
comply with Noosa to revetment wall with site welded connection development application.
Existing
Shire Council regulations 2/138x16mm composite decking legend
revetment wall
Existing
7000
fascia to perimeter Denotes dimension to centre line
7425
revetment wall
Denotes dimension to outside face
5500
138x25mm solid
composite decking
2750
aluminium framing sizes to engineers
Boundary
Boundary
design & detail
425 750
1500l x 425w
425
kayak step
1450l x 425w 315 dia. pvc insitu piles
8500 1500 750 750 to engineers detail
kayak steps
10000
floor plan floor framing & footing plan
1 1 : 100
2 1 : 100
2000
200 200
200
powdercoated
aluminium handrail
Boundary line
138x25mm solid 2/152x63x6mm structural
composite decking 'c' channel headstocks per pile
Do not fix jetty to Floor joists site welded to 200x50x3mm aluminium
140x20/25 h4 equivalent
revetment wall headstocks to engineers detail floor joists @ 450 crs max.
or class 1 timber decking
300mm deep fascia
2/138x16mm composite decking
typical handrail detail
Existing revetment wall
fascia to perimeter
4 1 : 50
Headstocks to piles to
engineers detail
floor areas
315 dia. pvc insitu piles jetty area 23.9 m²
to engineers details total area 23.9 m²
section signatures
3 1 : 50 owner/s
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 DAVID FENECH NEW JETTY FLOOR PLAN, FLOOR FRAMING PLAN & 02 B 25.048 A3
NORT
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
No. 18 THE PENINSULA, NOOSAVILLE Q 4566 TYPICAL SECTION SHEETS IN SET SCALE
H
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
B 21/08/25 SDK CONSTRUCTION ISSUE Lot 444 ON RP856191 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies