Original source · versioned page text
25.048_The Peninsula_Issue B_21Aug25(3)(1)(1)Building Design
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
property details
No. 18 The Peninsula
Noosaville QLD 4566
41.500m 107°20'0" Projected boundary Noosa Shire Council
Locality - Noosaville
1500 water allocation boundary Lot 444 on RP856191
Site Area - 789m²
peninsula
Existing jetty to water allocation area Zone - Low Density Residential
be removed Precinct - Nil
Boat lifting Overlays - Acid Sulphate Soils
10075
10075
- Flood Hazard
197°20'0"
device (8.5x3.5m)
17°20'0"
- Coastal Hazard
canal
10000 from revetment wall
proposed
jetty
19.000m
19.000m
8925
the
Floating cube
7425
Existing dock (2.5x5.0m)
revetment wall
1500 water allocation boundary
1500
41.500m 107°20'0" Projected boundary
15000
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 DAVID FENECH NEW JETTY SITE PLAN 01 B 25.048 A3
NORT
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
No. 18 THE PENINSULA, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
H
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
B 21/08/25 SDK CONSTRUCTION ISSUE Lot 444 ON RP856191 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies