tec sMic PROPOSED RESIDENTIAL DEVELOPMENT beste Rye Aether 39 PICTURE POINT CRESCENT, NOOSA HEADS 6.3. Building Foundations 6.3.1 Indicative Site Classification Site classifications for footing design are determined in accordance with AS 2870-2011 Residential Slabs and Footings, and depend on the depth of cut undertaken at a site, variations in the natural soil depths, and the reactivity of the in situ materials and any imported fill materials. Based on the results of the investigation, the site is classified as Class P in accordance with AS 2870-2011 Residential Slabs and Footings, due to the presence of poor bearing capacity soils at shallow depths and trees. If not for these factors, the site would have the characteristics of Class S, with the estimated characteristic surface movements (‘y;’) ranging up to about 20 mm. However, due to the potential variability in subgrade density a site classification of Class M is recommended in relation to assessment of flexibility requirements for ground slabs, footing and plumbing design. 6.3.2 Footing Design No design loadings were available at the time of reporting. Footings for the proposed development and any ancillary structures (e.g. retaining walls, etc.) must penetrate through any fill materials and unsuitable natural soils (i.e. very loose to loose and medium dense sands). Footings should be taken to found at least 7 m in to the underlying dense sands. This would result in relatively long piles ranging up to the order of 10 m BGL as shown indicatively in Text Figure 9. Concrete piles so founded may be designed using an ultimate end bearing pressure of 3 MPa, and ultimate side adhesion (in dense sand) of 60 kPa. Settlement under such loads is expected to be in the order of up to 20 mm or 1% of footing width. In addition, piles on the downslope edge of the buildings (at least) will likely be required to have resistance to normal shear forces. A review of the design plans should be undertaken, once available, such that the footing design for the structures can be optimised. Given the sandy soil profile and depths of footings required, steel screw piles could be considered a suitable foundation type, where more onerous shear resistance is not required. The use of driven piles would be precluded with the proximity to neighbouring residences, and the presence of sewer infrastructure within the site. Steel reinforced, concrete bored piles could be considered, however installation may not be straightforward, given the presence of very loose to loose sands in the upper soil profile. The use of a continuous flight auger, grout-injected pile system would be required for bored piles. The advice of a specialist piling contractor must be sought regarding feasibility, design and installation of the piling system for this site, including an assessment of potential vibration effects on nearby structures, and monitoring requirements. Depending on the detailed design of the footing system, once access becomes available (following building demolition) it is recommended that additional geotechnical investigation is undertaken to confirm parameters for piling. This should comprise two boreholes drilled to at least 2 m beyond the design pile toe depths (say about 12 m BGL) with standard penetration testing at regular, 1.5 m intervals. If steel screw piles are adopted, it will be important to ensure close supervision of installation, as piling may not encounter sufficient drilling resistance (from torque measurement) in sands at the suggested founding depth, and piles could extend to much greater depth than necessary. It is therefore recommended that site specific static load testing be conducted from screw piles, if adopted, at a minimum. Where tension or compression capacity developed in the footings is critical for the future structure (e.g. resistance to uplift forces from high winds), then cyclic load tests (including measurement of deflections under tension and compression cycles) should also be undertaken prior to construction. Kentledge for static testing, or simulated cyclic loads, should prove the piles to a minimum of two times the expected working load within tolerable deflections. Footing design should also account for potential soil reactivity to be equivalent to Class M. It should be noted that placement of reactive clay may result in a more severe equivalent site classification, such as H1 or greater. 10 February 2023 Report No. 22511-001-Rev0 14 65
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.