GENERAL NOTES
lot 206 on RP170380
109 cooyar street, noosa heads qld 4567 04 of 10 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
Elevation B 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
boundary line AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3770 3870 4930 1760 1500 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
Elevation A
MGP 10/MGP12
1920
6600 04 of 10 4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
400
dp 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
100
2950 2950 2502 SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
boundary line 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
300 6000 300 BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
450 9. BUILDER AND TRADES ARE TO CONFIRM ALL
MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
as constructed SETOUT AND ORDERING OF MATERIALS
6000
7000
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
carport AS NO RESPONSIBILITY WILL BE TAKEN AFTER
5910
CONSTRUCTION HAS COMMENCED
all other materials 11. ALL TRADES ARE TO CONFORM WITH THE
refer to specs sheet CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
300 100x100x3mm shs posts 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
100
400
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
1570
REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
existing 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
residence BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
7110
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
15830
Elevation D
NOOSA COUNCIL
04 of 10 REFERENCE DOCUMENT
Areas EXE25/0024 12 JUNE 2025
Name Area
carport 36.00 m²
AS CONSTRUCTED
existing floor
Grand total 36.00 m²
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: ANNE-MAREE + BUILDER: MANDY'S DESIGN + DRAFTING SHEET: 2 of 3 DATE: ISSUE NO:
AS CONSTRUCTED CARPORT ROB FEWTRELL PH: 0401 910 388 OWNER BUILDER PH: 0403 481 474 QBCC: 15117996 SCALE: 1:100 19 FEB 2025 AR-2025-D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Reference Documents - EXE25 0024 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.