GENERAL NOTES
lot 206 on RP170380
109 cooyar street, noosa heads qld 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
existing residence
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
as constructed carport GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
TOP PLATE SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
JOINERY LINE 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
1920 TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
2740
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
2100
boundary line
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
FLOOR MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
300
SETOUT AND ORDERING OF MATERIALS
PAD LEVEL 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
850
100x100x3mm shs posts
Elevation A AS NO RESPONSIBILITY WILL BE TAKEN AFTER
CONSTRUCTION HAS COMMENCED
11. ALL TRADES ARE TO CONFORM WITH THE
CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3660.1.2000
existing residence
DOMESTIC SMOKE ALARMS
300 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
2515
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
as constructed carport WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
details refer materials REGULATION 2016
1.00° 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
angled boundary 2515 at shortest end
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
residence
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
2740
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
900
GLAZING
Elevation B 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
2815 TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
PRIVACY OPTIONS
ELECTRICAL AND ENERGY EFFICIENCY
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
(heights to be confirmed)
INDICATIVE ONLY
as constructed carport
1.00° DOWNPIPES
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
angled boundary 3115 at shortest end
CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
3115
overall height
3593
existing elevations
900
NOOSA COUNCIL
AS CONSTRUCTED Elevation D REFERENCE DOCUMENT
EXE25/0024 12 JUNE 2025
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: ANNE-MAREE + BUILDER: MANDY'S DESIGN + DRAFTING SHEET: 3 of 3 DATE: ISSUE NO:
AS CONSTRUCTED CARPORT ROB FEWTRELL PH: 0401 910 388 OWNER BUILDER PH: 0403 481 474 QBCC: 15117996 SCALE: 1:100 19 FEB 2025 AR-2025-D
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Compiled Reference Documents - EXE25 0024 (As Published).pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.