Original source · versioned page text
Attachment 5 - Environmental Noise Assessment
2 Noise Monitoring
2.1 Noise Measurement Methodology
Noise measurements were taken continuously over a four-day period commencing Saturday 22nd
May to Wednesday 26th May 2021. The following information was detailed:
➢ Measurements were completed on the site using a Type 1 Sound Level Meter, Rion NL 54
(s/n 00297846);
➢ The sound level meter holds current laboratory certificate of calibration, available upon
request;
➢ The meter was calibrated before and after the measurements and was found to be within
0.1dB of the reference signal;
➢ The meter records both slow and fast time weighted sound levels, along with statistics
throughout the measurement period, allowing relevant data to be collected;
➢ The microphone was fitted with a standard wind screen;
➢ During the measurements, the microphone was located at a height of 1.4 metres above the
ground level and at least 3 metres from reflecting facades (other than the ground plane); as
such no adjustments have been applied for reflected noise.
Average meteorological conditions at the time, recorded at the Bureau of Meteorology’s Tewantin
site, were:
➢ Temperature: 13.2 – 25.7oC
➢ Relative Humidity (avg): 81%
➢ Periods of rainfall omitted from the data.
2.2 Ambient Noise Monitoring
The results of the noise logging is summarised in Table 2.1. Figure 2.1 presents a chart of the
measured noise levels.
Ref: 21030929 - 01a Page 6 of 24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.