Original source · versioned page text
Attachment 1 - Development Approval TPC1957
Fils
Raul weycharat | SCANNED
meer) REGISTERED
Je H.
19th November, 1987
Hooton Pty. Ltd.,
NOOSA HEADS. 0. 4567
Dear Sirs,
Re:
Application for Town Planning Consent (TPC 1957) for eighty (80)
dwelling units and ancillar facilities at Gympie Terrace, Thomas
Street and The Cockleshell, Noosaville comprising various parcels
With reference to the above application I wish to advise that Council at
meeting held on 17th: ‘November, » 1987. resolved. to propose. to approve the.
application . subject. to ‘the: ‘following conditions :=
its
1.
Ze
3
Submission to and approval by Council of building plans in accordance
with the Building Act, Council's By-laws and Policies, and generally
in accordance with the plan approved in this Consent and the Shire of
Noosa Town Planning Scheme apart from where amendments are required by
dispensations or have been granted in conjunction with this Consent.
The plans submitted for Building Approval are to comply with the
following requirements:-
(i) Shops 1 and 2 are to have a 1.5 metres side setback.
(ii) Carparks and driveways are to be setback 2.0 metres from
boundaries or 0.5 metres minimum if a screen fence is provided.
Provision of. atleast one hundred . (100)° off-street . car. parking. spaces,
comprising eighty — (80) covered. “gpaces and” “twenty — (20) uncovered °
spaces, and access thereto which are to be provided with a sealed
pavement and designed, drained, constructed and maintained in
accordance with the Town Planning Scheme, Council's Policies and to
the reasonable satisfaction of the Shire Engineer. Plans and
specifications (prepared by by a registered Civil Engineer) for these
works are to be submitted to the Shire Engineer for approval in
conjunction with the Building Application.
There is to be no detrimental effect upon the amenity of the
neighbourhood by reason of the creation of excessive noise, lighting
nuisance or other emissions.
200306_kodakscanner_101319_001.tif
REFERS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 8 pages
Page 2
J.H. Hooton Pty. Ltd. ~. TPC 1957 - 19th November, 1987 - Page 2 5. The open space and setback areas are to be Landscaped in accordance with the Noosa Design Manual and a properly prepared Landscaping plan to be . submitted to and approved by the Shire Planner, prior to the issue of a Building. Approval. Such landscaping is to be completed in . accordance with the approved landscaping plan, prior to the premises ‘being occupied and maintained at all times thereafter to the reasonable satisfaction of the Shire Planner. 6. Existing trees are to be retained, except where required to be removed - due to building operations or the conduct of the approved use. 7 Construction work is permitted only during the hours of 7.00 a.m. to 6.00 p.m. Monday to Saturday, except where extended hours are approved by the Building Surveyor. : Any advertising sign or device is to comply with the provisions of the Noosa Design Manual. The developer is to submit an overall Concept plan for signage prior to the issue of a ‘pufiding: permit. 9, Payment of contributions in accordance with Council's Policy on.Water Supply and Sewerage Headworks, current at the time of Building Approval. Calculations based upon the current Policy including Price Index variation as at October, 1987 are estimated as follows:- Water Supply - $125, 491 Sewerage ~ $ 51,444 TOTAL: $176, 935 The headworks figures are for the units only with additional headworks to be paid in respect of the shops. If payment is not proposed to be made prior to the issue of Building Approval, a cash bond or trading bank guarantee for the required amount is to be lodged prior to the release of that Approval. The contribution is then required to be made within fourteen (14) days of the issue of Building Approval. 10. The developer shall bear the cost of alteration of any public utility or facilities necessitated by the development of the lénd or associated construction works external to the site. | 11. Floor levels for all buildings and other structures, car park areas and fill levels for the site are to be in accordance with the requirements of the Shire Engineer. Such levels shall be provided on application to the Council's Engineering Department. Any filling or other development works undertaken on the site shall be carried out so as not to cause the ponding of water on any adjoining lands and the blockage or interference with any natural watercourses. No earthworks or filling works are to be undertaken until issue of a Building Approval.
Page 3
J. H. 12. 13. 14. 15. 16. 17. Hooton Pty. Ltd. - TPC 1957 - 19th November, 1987 - Page 3 seo et wate Prior to finalisation of Building Plans, the applicant shall submit a detailed layout of the carparking and driveway areas. Such layout shall be in accordance with Council's Policies and standard drawings and shall specifically allow for a total of 4 loading bays on site. Roof and surface water is to be collected on site and discharged into Council's existing drainage system, in accordance with Council's Master Drainage Plan, to the satisfaction of the Shire Engineer. A full design of the proposed drainage system is to be submitted to Council for approval prior to issue of a building permit. The design shall include an assessment of the adequacy of Council's existing stormwater drainage at the discharge points of the internal system. The stormwater drainage system shall be designed so that suitable escape routes are available to accommodate stormwater in excess of the design storm frequency. The footpaths to the full frontages of the site are to be landscaped and upgraded to _ the satisfaction of the Shire Engineer. In this regard, a detailed landscaping plan of the proposed works is to be submitted for approval prior to the issue of a Building Permit. A minimum 1.2 m. wide footpath is to be provided on the Cockleshell frontage with the Thomas Street and Gympie Terrace frontages to be fully paved. Existing access crossovers not required to service the development are to be reinstated with kerb and channel to the satisfaction of the Shire Engineer. Such works shall include repairs to damaged sections of the existing kerb and channel as a result of the previous uses on the site. Prior to commencement of filling works, the applicants' ‘consultants shall submit, for approval by the Shire Engineer, an engineering study of the implications of the filling works in relation to the drainage petterns of adjoining lots. Such report shall include sufficient survey information, external to the site, to accurately determine the existing drainage flows, in addition to recommended drainage works on the perimeter of the site to prevent possible drainage problems on adjoining lots. All ‘drainage works necessitated by the development shall be at the full expense of the developer. Connection to Council's existing water supply reticulation system at the developer's expense to the standards and requirements of Council's Shire Engineer. The applicant's Hydravlic Consultant shall design the internal water reticulation system to provide a service to each unit in accordance with the Department of Local Government Guidelines. Any upgrading works required to Council's existing system to provide the required flow rates shall be at the Developer's full expense. .
Page 4
J.H. Hooton Pty. Ltd. - TPC 1957 - 19th November , 1987 - - Page 4
18.
a
The proposed layout of units is not approved due to conflict with
existing sewer mains. Should the’ applicant so desire Council would
consider relocation of the sewer mains within the site to suit. the
proposed unit layout. However the following requirements would
apply :~
(a) Full engineering design of the proposed sewer construction would
need to be submitted to Council for approval. Costs of checking
of designs by Council's sewerage consultants would need to be
borne by the applicant.
{b) The unit layout shovld not be finalised in relation to
preparation of building plans until consideration by Council of
the sewer relocation design and the required offsets from the
sewers to any buildings.
(c) All requirements concerning relocation of the sewerage facilities
and connection to existing mains shall be carried out to
Council's standards and requirements.
{d} Sewer relocation works shall be completed prior to building works
commencing in the vicinity of these sewers.
(e) No building approval will be issued until consideration and
approval of the sewer designs by Council's Shire Engineer.
(£) The sewer design shall be carried out so that access to ail
sewers within the site is available for Council for future
maintenance works. Council will not accept any buildings or
associated facilities such as swimming pools being construction
ever the sewers. The sewers should be located such that grassed
open areas or driveways are constructed over the sewer lines.
(g) Any existing connection points to the sewer to existing services
shall be closed off to the satisfaction of the Shire Engineer.
(h) Any sewers that are to remain in place after the development
construction shall be inspected by Council as to their condition
to allow any remedial works to be carried out prior to
construction works being carried out near the sewers.
(i) At the design stage the capacity of the existing sewers which
will serve the site shall be checked as to the adequacy of their
capacity to handle the design loading. Shouid any augmentation
be required to cater for the development this shall be carried
out at the full cost of the developer.
(j} A sewer connection point shall be provided for each unit and shop
in the proposed development.
Page 5
J.H, Hooton pty. itd, - TPC 1957 - 19th November, 1987 - Page 5 (k) No encroachment of buildings or other structures is permitted . into Council's sewer rising main easement. 19. Provision of approved refuse containers in accordance with the requirements of the Refuse Management Regulations of 1983 for the storage and collection of refuse to the satisfaction of Council's Health Surveyor. 20. Provision of an imperviously paved, drained and enclosed area to accommodate all refuse containers to the reasonable satisfaction of Council's Health Surveyor. This area is to be aesthetically screened from any road frontage or adjoining property boundary and is to be | setback a distance of two (2) metres from any road frontage. A suitable hosecock and hoses to be located in the vicinity of the refuse container area. 21. Any flat, or unit intended to be let out for fee or reward is to be Licenced annually with Council's Health Department in accordance with the provisions of Chapter 43 of © ‘Council's. By-Laws prior to such letting. | 22. The swimming pool shall be licensed annually with the Council's Heaith Department in accordance with the provisions of . Chapter 42° -of Council's" Bye Laws - 23. The footpath and setback areas are to be kept clear of goods, signs and street furniture not approved by Council. 24. Should S.E.Q.E.B. require provision of a transformer, such provision is to be made to the satisfaction of S.E.Q.E.B. and the Shire Planner. The transformer is not to be located within landscaping areas unless approved by the Shire Planner. 25. Submission of a cash bond or trading bank guarantee to the sum of $200,000, prior to the issue of Building Approval: (a) against payment of water supply and sewerage headworks charges ($176,935); (b) to secure performance of conditions ($23, 065); The cash bond or trading bank guarantee may be returned to the applicant upon payment of the required sums and performance of the conditions of approval. 26. The provisions of this Town Planning Consent are to be effected, prior to the commencement of the specific use granted under this Consent Council reserves the right to call upon the bond or guaranteed sum referred to in this approval for the purposes of Litigation should the use not be conducted in accordance with this Approval.
Page 6
J.H. 27. 28. Hooton Pty. Ltd. - TPC 1957 - 19th November, 1987 - Page 6 erp This Consent may be revoked pursuant to Section 33 (16D) of the Local Government Act if substantial progress has not been made in the erection of any building or other structures in accordance with this Consent or the rights conferred by this Consent are not exercised in accordance with this Consent within two. (2) years of the date thereof. The ‘Applicant shall dedicate to Council, at no cost to Council, a 3.66 m. wide easement over Council's existing sewer rising main through the site. In this regard, the easement documentation shall be prepared by Council's Solicitor and shall be executed by both parties prior to the issue of a building permit. An appropriate undertaking for the production of the Title Deed at the Titles Office by the Applicant's Solicitor shall be given to Council's Solicitor. Please find attached for your information :- (a) (b) You List of names and addresses of objectors to the application; and Copies of relevant parts of the Local Government Act outlining appeal rights with respect to Council's decision. will be further - advised following the expiry of the thirty (30) day — appeal period mentioned in Section 33 (18) (i) of the Local Government Act. Enc. Yours faithfully a Ett, D.J. Philpot SHIRE CLERK (CX
Page 7
ABS SECTION - we THE -COCKLESHELEL wee -COCKLE SHELL - Kye | THE SITE DATA ‘SITE sez M? GEA ALLOWED MMO M2 ACTUAL 850) HT - THOMAS - STREET - “SITE PLAN: “TERRACE GYMPIE gongm °° Po tare a Sr ease T oe “Gian sorkey + ossockates ty. |*THinpoTON Pry uD |* Hise aS MO Wefe Mend MOOKAMLUE usee ene KOH U0 208 rrr ‘MITE PLAN
Page 8
‘alan \° Ore
= 06 * Sarkey + associates pty. td. |" TH HooTON PTY LTO |"NOOSA ISLANDER
Be sate eocete orn an 208 |
Page 9
gs
T
fae ficor plan
i f
= oo oa em
ion : ae Noo i [eee
es dion starkey + associates ply | y+ HOOTON PTY LID | NOOSA ISLANDER FLOOR PLANS ex eorat 329SKB)
7 Werte eed MOOSKMLLE 4584 Plone lor unr zee 1 _A "ito |