                                                                                                                                                                                                                                                                                                     Project Job No. 173527



                                                                                                                                Plumbing Guidelines
                                                                                                                  Edge Beam and Slab Thickening Pipe Penetrations


                                Edge Beam Footing                                                       Slab Thickening




                                                                                                                                                                                                                                           Slab Surface

                                                                                                                                                           Not Allowed                                                                             Slab Fabric
         Not Allowed                                                                                                                                                                     D/3            Not Allowed

                                                                                                                                                           Refer Detail
                                                         Pipe and Lagging                                                               Pipe and Lagging   Below
         Allowed                                                                                                                                                                                                                                                       D = Depth of Footing + Slab
                                                                                                                                                                                         D/3            Allowed                        Pipe and Lagging
         Providing Min Footing Depth
         Maintained Below Pipe
                                                             Nominated Footing         Reinforcement
                                                             Depth Must be
         Refer Detail                                        Maintained Below                                                                              Allowed                                      Refer Detail
                                                                                                                                                                                         D/3
         Below                                               Pipe                                                                                                                                       Below

                                                                                 Notes:                                                                                                                                                    Base of Footing
         Allowed                                                                 The edge beam or slab thickening reinforcement shall not                                                                   Allowed
                                                                                 be cut to allow for the placement of pipes. If the pipe is to
                                                                                 be located in this area the footing must be excavated
          Where the Pipe                                                         deeper to allow for the placement of the reinforcement.
          Passes Beneath
                                                             300 Min             The edge beam must not be jackhammered for the
          the Footing, Piers
                                                                                 placement of pipes.
          are to be Placed
                                                                                 When the pipe penetrates the footings or
          in this Area
                                                                                 slab thickenings within the lower 1/3 they
                                                                                 must be excavated deeper to maintain
                                                                                 the cover as specified.




                                                                                                                                                                                          Local Deepening of Edge Beam Footing or Slab Thickening
                             Edge Beam Footing                                              Slab Thickening


                                                                                                                                                                                                                                                Slab Mesh



                                                                                                                                                                                        Trench Mesh
                                                                                                                                                                                                                                                  40 mm Min Cover
                                                                                                                                                                                                        40 mm Min Cover
                                                                                                                                                 Nominated Depth

                                                                                                                       Pipe and Lagging
                                                                                                                          40 mm Min Cover                                                                       1000 mm                             1000 mm
                                                                                                                                                 Extra Depth
                                                                       Reinforcement
Nominated Footing                                                                                                         40 mm Min Cover
                                                                                                                                                                                                                        When the pipe penetrates the footings or
Depth                                                                                                                                                                                                                   slab thickenings within the lower 1/3 they
                                                       Pipe and Lagging                                                                                                                                                 must be excavated deeper to maintain
                                                                                   When the pipe penetrates the footings or
                                                                                                                                                                                                                        the cover as specified.
                                                         40 mm Min Cover           slab thickenings within the lower 1/3 they
Extra Depth                                                                        must be excavated deeper to maintain
                                                         40 mm Min Cover           the cover as specified.

                                       Reinforcement
                                                                                                                                                                                                    Service Line Location and Piering

                                                               Minimum Pipe Lagging




                                                                                                                                                                            The service trenches must not
                                                                                                                                                                            be located within the zone of             Zone of
                                                                T                                                                                                           influence of the footings.                Influence
                                                                                                                                                                            Alternately the edge beam
                                                         CLASS         LAGGING THICKNESS (T)                                                                                be piered below the zone of                              45 Degrees for Clay Soils
                                                                                                                                                                            influence of any services.                               30 Degrees for Sand Soils and Fill
                                                           S, M                        20
                                                                                                                                                                                                                 300 Min
                                                        H1, H2, E                      40




   STA CONSULTING ENGINEERS
Brisbane North (Milton) (07) 3071 7444 Brisbane South (Rocklea) (07) 3071 7444 Gold Coast (07) 5522 1995 Mackay (07) 4960 4800
                                                                                                                                                                   Client
                                                                                                                                                                   DJK Electrical Services
                                                                                                                                                                                                                                                                     Site Address
                                                                                                                                                                                                                                                                     Lot 497 10 HILL STREET SUNSHINE BEACH
                         Townsville (07) 4766 8741 Rockhampton (07) 4994 9810 Newcastle (02) 4032 6450                                                             TBA SUNSHINE BEACH 4567                                                                           4567
                                                                                                                                                                                                                                                                                                                 Page 10 of 14
                              email: [email protected] webpage: www.staconsulting.com.au
                                                                                                                                                                                                                                                             STDCON 2014-14-05

Used in these records

About this file

File size
835 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

ES_173527_BR_1059006_Conv_Lot 497 10 HILL STREET SUNSHINE BEACH QLD(C).pdf · 835 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.