Project Job No. 173527
Plumbing Guidelines
Detail 1. Scale: 1:25 Detail 2. Minimum Heights of Slabs Above
Services Under Slab Services Under Slab Ground for Habitable Rooms
- 150 For High Side of Well Drained Sites
Edge Beam Relief Gully - 300 For Level, Poorly Drained Sites
Stainless Steel Strap and Bolts Fixed
All Slab to Reinforcing Steel. Only to be Lowest
Penetrations to Termite Protection to AS 3660.1 Used Where Fill Material Depth Fixture
be Sealed to Exceeds 900 mm Under Wet Areas.
Relief Gully Trap to be Min.
AS 3660.1
150 Below Lowest Fixture
FLOOR LEVEL
Fall
(min)
50
Min 1:20
(50 mm over 1.0 m)
75
Ground Level
to be 75 Below
Top of Gully Trap
(max)
600
Stainless Steel Strap
and Bolts Fixed to
Reinforcing Steel. Drainage Channel Must
Only to be Used be Wide Enough to Take All
Where Fill Material Water Without Flooding the Spacing For Straps:
Dwelling Pier For Pipes > Ø 100 mm Max Spacing 1200 mm Max
Exceeds 900mm Under
Pier
Wet Areas. For Pipes <= Ø 100 mm Max Spacing 1000 mm Max
Spacing For Straps:
For Pipes > Ø 100 mm Max Spacing 1200 mm Max
For Pipes <= Ø 100 mm Max Spacing 1000 mm Max
Strap Spacings
Strapping of under slab pipework is required where uncompacted fill Detail 3.
Underslab Plumbing has been identified or as a result of cut / filling operation in the
Downpipe Articulation For
construction of the building pad. Strapping is to be placed where the
Plumbing, sewage and drainage services shall be located and installed so as to ensure:
- The functioning of the footings and slabs on-ground are not impared.
fill depth excededs 900mm.
Uncompacted fill being material that is not natural ground or having had
"M' Soil Classification
- The functioning of the services themselves are not impared.
Water pipes must not be laid horizontally in slabs, but may be placed vertically as a
compaction as AS 3798 (Level One Supervision)
penetration, as detailed above. 1. For main drains Ø >100 mm strapping to be placed at the head and
then at 1200mm max. spacing.
Notes: 2. For smaller pipework Ø <100 mm (eg sink & floor waste), Strapping
to be placed at the head and then at 1000 mm max. spacing.
1. All plumbing (within & beyond the footprint of the slab & footings) to be constructed 3. For pipework passing under the footing, place strapping as 90 mm
Downpipe
in accordance with AS3500 - National Plumbing & Drainage code. close as practicable to the inside edge of the footing.
2. All PVC pipe work passing horizontally through concrete must have 20 mm for 'H' or
4. For pipework passing through the footing, place strapping at Slip Joint
40 mm lagging for 'E' sites. Sleeves allowing equivalent movement may be used as an
1200 max. from inside edge of the footing. Coupling
alternative.
3. Corrugated flexible PVC pipe should not be used for sanitary (sewer) pipes as it is not 100 (min)
able to expand to accommodate soil movement.
100 (min)
Advice to Plumbers Typical Detail
Ensure that no piers are accidentally dislodged during trench Backfilling of Trench
excavation. If this happens, advise site supervisor immediately.
Backfill with compacted clay soils
or equivalent to form an impermeable
Construction Sequence layer to all trenches within 1500 mm of
the building
100 mm
Pier
Underground
1. Pad Leveled Stormwater Line Note: The slip coupling joints may be
Minimum
2. Slab Set Out Natural Surface substituted for flexible sub-surface pipes
300
3. Under Slab Plumbing which comply with AS/NZS3500.3 and
4. Piering and AS/NZS 2566.1
5. Steel Up
Varies
Backfill
Depth
6. Concrete Pour Approved bedding
materials to
appropriate cover
Site Classification
P/S
Clay Plug to full
depth of bedding Note: If the site is classified as a Class
at footing zone
Width Varies
P the plumbing it to be done as per the
soils characteristic reactivity noted on
Typical Trench Detail page 1 of the report.
STA CONSULTING ENGINEERS
Brisbane North (Milton) (07) 3071 7444 Brisbane South (Rocklea) (07) 3071 7444 Gold Coast (07) 5522 1995 Mackay (07) 4960 4800
Client
DJK Electrical Services
Site Address
Lot 497 10 HILL STREET SUNSHINE BEACH 4567
Townsville (07) 4766 8741 Rockhampton (07) 4994 9810 Newcastle (02) 4032 6450 TBA SUNSHINE BEACH 4567
email: [email protected] webpage: www.staconsulting.com.au Page 11 of 14
STDCON.2014-14-05
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
ES_173527_BR_1059006_Conv_Lot 497 10 HILL STREET SUNSHINE BEACH QLD(C).pdfRelated documentApplication case desk ↗
About this file
- File size
- 835 KB (small file)
- File type
No other editions are linked here.