Council archive · source document
ES_173527_BR_1059006_Conv_Lot 497 10 HILL STREET SUNSHINE BEACH QLD(C) · MCU18/0006.02
Attached to the e-mail Hill Street .msg.
Attached to the e-mail Hill Street, .eml, inside Generally in Accordance Application MCU18/0006.02 - Cover email - Plans.
Project Job No. 173527
Section 5 - Drainage & Articulation Requirements
Wall /Eaves Junctions
Typical Vertical Articulation Joint Details
Single Skin Masonry Cavity Wall Extendible Anchors
Compressible foam joint
filler and mastic-backing Eaves Detail - Roof Supported On External
built in by bricklayer Leaf of Masonry Wall
Boxed or (horizontal) soffit-lined eaves
External wall supports roof structure
eaves supoort framing, fixed to roof
framing and not masonry wall
Alternative raked
eaves lining
Horizontal eaves lining
Optional cover moulding fixed Eaves lining above external External masonry wall
to supporting timber for wall and window/door heads stops under eaves lining
Mastic sealant horizontal eaves or rafter/
top plate for raked eaves
Alternative Articulation Joint Detail
For External Masonry Wall
Masonry expansion Gap formed by
(Sliding/extendable) tie temporary filler
Wall /Ceiling Junctions
Backer rod*
Elastomeric sealant
10mm
Perimeter Wall With Framed or Trused Roof
*Open-cell polyurethane or
closed-cell polyethylene (Internal wall with framed roof similar detail)
to ensure proper sealant Cornice fixed to roof framing only Internal Wall With Trussed Roof
10mm minimum
dimensions allowing movement of masonry wall Bottom chord of roof truses
Fixing of Window /Door Frames at Articulation Joints Gap sufficient Cornice fixed to roof
to allow for truss only allowing
expected movement movement of
masonry wall
Note:
Various tie types
available
Masonry expansion tie Architrave conceals join on inside
screwed to window frame
Window/Door frame
Cover moulding conceals
articulation joint on outside
Gap
STA CONSULTING ENGINEERS
Brisbane North (Milton) (07) 3071 7444 Brisbane South (Rocklea) (07) 3071 7444 Gold Coast (07) 5522 1995 Mackay (07) 4960 4800
Client
DJK Electrical Services
Site Address
Lot 497 10 HILL STREET SUNSHINE BEACH 4567
Townsville (07) 4766 8741 Rockhampton (07) 4994 9810 Newcastle (02) 4032 6450 TBA SUNSHINE BEACH 4567
STDCON.2014-14-05
email: [email protected] webpage: www.staconsulting.com.au Page 12 of 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
ES_173527_BR_1059006_Conv_Lot 497 10 HILL STREET SUNSHINE BEACH QLD(C).pdfRelated documentApplication case desk ↗
About this file
- File size
- 835 KB (small file)
- File type
No other editions are linked here.